For Leuze MLC 510 / 520 Series Light Curtain Sensor Replacement 40 mm Resolution 20M Sensing Distance 150 mm to 2850 mm Protection Height
- Model
- MLC 510 / 520 Series | MLC500T40-150, MLC520R40-150, MLC500T40-225, MLC520R40-225, MLC500T40-300, MLC520R40-300, MLC500T40-450, MLC520R40-450, MLC500T40-600, MLC520R40-600, MLC500T40-750, MLC520R40-750, MLC500T40-900, MLC520R40-900, MLC500T40-1050, MLC520R40-1050, MLC500T40-1200, MLC520R40-1200, MLC500T40-1350, MLC520R40-1350, MLC500T40-1500, MLC520R40-1500, MLC500T40-1650, MLC520R40-1650, MLC500T40-1800, MLC520R40-1800, MLC500T40-1950, MLC520R40-1950, MLC500T40-2100, MLC520R40-2100, MLC500T40-2250, MLC520R40-2250, MLC500T40-2400, MLC520R40-2400, MLC500T40-2550, MLC520R40-2550, MLC500T40-2700, MLC520R40-2700, MLC500T40-2850, MLC520R40-2850
Item specifics
- Series:
- MLC 510 / 520 Series
- Resolution:
- 40 mm
- Scanning range:
- 0 - 20 m
- Protective field height:
- 150 - 2850 mm
- 2 Safety outputs (OSSD):
- 2 PNP
- Response time:
- 3 - 25 ms
- Connection type:
- M12
- Security level:
- PLe4
Review
Description
For Leuze MLC 510 / 520 Series Light Curtain Sensor Replacement 40 mm Resolution 20M Sensing Distance 150 mm to 2850 mm Protection Height Parameter
Brand | Transmitter | Receiver | DADISICK |
|
Models | MLC500T40-150 | MLC520R40-150 | QT04-40-120 2BE | |
MLC500T40-225 | MLC520R40-225 | QT06-40-200 2BE | ||
MLC500T40-300 | MLC520R40-300 | QT08-40-280 2BE | ||
MLC500T40-450 | MLC520R40-450 | QT12-40-440 2BE | ||
MLC500T40-600 | MLC520R40-600 | QT16-40-600 2BE | ||
MLC500T40-750 | MLC520R40-750 | QT20-40-760 2BE | ||
MLC500T40-900 | MLC520R40-900 | QT24-40-920 2BE | ||
MLC500T40-1050 | MLC520R40-1050 | QT26-40-1000 2BE | ||
MLC500T40-1200 | MLC520R40-1200 | QT30-40-1160 2BE | ||
MLC500T40-1350 | MLC520R40-1350 | QT34-40-1320 2BE | ||
MLC500T40-1500 | MLC520R40-1500 | QT38-40-1480 2BE | ||
MLC500T40-1650 | MLC520R40-1650 | QT42-40-1640 2BE | ||
MLC500T40-1800 | MLC520R40-1800 | QT46-40-1800 2BE | ||
MLC500T40-1950 | MLC520R40-1950 | QT50-40-1960 2BE | ||
MLC500T40-2100 | MLC520R40-2100 | QT54-40-2120 2BE | ||
MLC500T40-2250 | MLC520R40-2250 | QT58-40-2280 2BE | ||
MLC500T40-2400 | MLC520R40-2400 | QT60-40-2360 2BE | ||
MLC500T40-2550 | MLC520R40-2550 | QT64-40-2520 2BE | ||
MLC500T40-2700 | MLC520R40-2700 | QT68-40-2680 2BE | ||
MLC500T40-2850 | MLC520R40-2850 | QT72-40-2840 2BE | ||
Beam spacing | 40 mm | 40 mm | ||
Protected altitude | 150 mm, 225 mm, 300 mm, 450 mm, 600 mm, 750 mm, 900 mm, 1050 mm, 1200 mm, 1350 mm, 1500 mm, 1650 mm, 1800 mm, 1950 mm, 2100 mm, 2250 mm, 2400 mm, 2550 mm, 2700 mm, 2850 mm | 120 mm, 200 mm, 280 mm, 440 mm, 600 mm, 760 mm, 920 mm, 1080 mm, 1160 mm, 1320 mm, 1480 mm, 1640 mm, 1800 mm, 1960 mm, 2120 mm, 2280 mm, 2360 mm, 2520 mm, 2680 mm, 2840 mm | ||
Scanning range | 0 - 20 m | 0.3 - 20 m | ||
Response time | 3 - 25 ms | ≤15 ms | ||
Output method | 2 PNP | 2 PNP | ||
Reliability and durability | IP65 | IP65 | ||
Connector | M12 | M16 | ||
Housing cross-section | 35.4 mm x 29 mm | 51 mm x 35 mm | ||
Safety Certificate | KCs, TÜV Süd, c TÜV NRTL US, c UL US, PLe4 | TUV, UL, CE, RoSH, GB | ||
We are able to reproduce the specific connection configuration of each brand with high level of accuracy. |
Product model display instructions
The brands and specifications shown on this page are for product selection only. Our safety light curtain is a safety part made by DADISICK, not official brand Leuze's products. DAIDSICK offer replacement for official brand products. We are not the owner of the brands. If you need to buy official brand products, please contact the brand official representative.
Product recommendations
Model:
QT04-40-120 2BE, QT06-40-200 2BE, QT08-40-280 2BE
QT12-40-440 2BE, QT16-40-600 2BE, QT20-40-760 2BE
QT24-40-920 2BE, QT28-40-1080 2BE, QT30-40-1160 2BE
QT34-40-1320 2BE, QT38-40-1480 2BE, QT42-40-1640 2BE
QT46-40-1800 2BE, QT50-40-1960 2BE, QT54-40-2120 2BE
QT58-40-2280 2BE, QT60-40-2360 2BE, QT64-40-2520 2BE
QT68-40-2680 2BE, QT72-40-2840 2BE
FAQ
1.What are the conditions for the safety light curtain to be working properly?
When the emitter and receiver are in working condition, the emitter's red light remains on, and the receiver's green light is illuminated. When the light curtain is obstructed, there is no change in the emitter's indicator light, but the receiver's light changes from green to red, and the digital display shows the number of blocked light beams. When there is no obstruction, the receiver returns to its normal state with a constant green light.
2. Does the supplier provide training and documentation on installation and operation?
Yes, we provide installation and operation guidelines, as well as safety regulations. You can also request training services to ensure that your team can correctly install and maintain the new light curtain.
3: What tests should I perform after installing a new light screen?
We suggest conducting functional testing and security verification to ensure that the new light curtain can function properly. The testing items include detection range, response time, and alarm function.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.