For Leuze MLC 510 / 520 Series Light Curtain Sensor Replacement 20 mm Resolution Palm protection 225 mm to 1800 mm Protection Height
- Model
- MLC 510 / 520 Series | MLC500T20-225H, MLC520R20-225H, MLC500T20-300H, MLC520R20-300H, MLC500T20-450H, MLC520R20-450H, MLC500T20-600H, MLC520R20-600H, MLC500T20-750H, MLC520R20-750H, MLC500T20-900H, MLC5250R20-900H, MLC500T20-1050H, MLC520R20-1050H, MLC500T20-1200H, MLC520R20-1200H, MLC500T20-1350H, MLC520R20-1350H, MLC500T20-1500H, MLC520R20-1500H, MLC500T20-1650H, MLC520R20-1650H, MLC500T20-1800H, MLC520R20-1800H
Item specifics
- Series:
- MLC 510 / 520 Series
- Resolution:
- 20 mm
- Scanning range:
- 0 - 15 m
- Protective field height:
- 225 - 1800 mm
- 2 Safety outputs (OSSD):
- 2 PNP
- Response time:
- 5 - 31 ms
- Connection type:
- M12
- Security level:
- PLe4
Review
Description
For Leuze MLC 510 / 520 Series Light Curtain Sensor Replacement 20 mm Resolution Palm protection 225 mm to 1800 mm Protection Height Parameter
Brand | Transmitter | Receiver | DADISICK |
|
Models | MLC500T20-225H | MLC520R20-225H | QT12-20-220 2BD | |
MLC500T20-300H | MLC520R20-300H | QT16-20-300 2BD | ||
MLC500T20-450H | MLC520R20-450H | QT24-20-460 2BD | ||
MLC500T20-600H | MLC520R20-600H | QT30-20-580 2BD | ||
MLC500T20-750H | MLC520R20-750H | QT38-20-740 2BD | ||
MLC500T20-900H | MLC5250R20-900H | QT46-20-900 2BD | ||
MLC500T20-1050H | MLC520R20-1050H | QT50-20-980 2BD | ||
MLC500T20-1200H | MLC520R20-1200H | QT60-20-1180 2BD | ||
MLC500T20-1350H | MLC520R20-1350H | QT68-20-1340 2BD | ||
MLC500T20-1500H | MLC520R20-1500H | QT76-20-1500 2BD | ||
MLC500T20-1650H | MLC520R20-1650H | QT84-20-1660 2BD | ||
MLC500T20-1800H | MLC520R20-1800H | QT90-20-1780 2BD | ||
Beam spacing | 20 mm | 20 mm | ||
Protected altitude | 225 mm, 300 mm, 450 mm, 600 mm, 750 mm, 900 mm, 1050 mm, 1200 mm, 1350 mm,1500 mm,1650 mm, 1800 mm | 220 mm, 300 mm, 460 mm, 580 mm, 740 mm, 900 mm, 980 mm, 1180 mm, 1340 mm, 1500 mm, 1660 mm,1780 mm | ||
Scanning range | 0 - 15 m | 0.3 - 15 m | ||
Response time | 5 - 31 ms | ≤15 ms | ||
Output method | 2 PNP | 2 PNP | ||
Reliability and durability | IP65 | IP65 | ||
Connector | M12 | M16 | ||
Housing cross-section | 53 mm x 29 mm | 51 mm x 35 mm | ||
Safety Certificate | KCs, TÜV Süd, c TÜV NRTL US, c UL US, PLe4 | TUV, UL, CE, RoSH, GB | ||
We are able to reproduce the specific connection configuration of each brand with high level of accuracy. |
Product model display instructions
The brands and specifications shown on this page are for product selection only. Our safety light curtain is a safety part made by DADISICK, not official brand Leuze's products. DAIDSICK offer replacement for official brand products. We are not the owner of the brands. If you need to buy official brand products, please contact the brand official representative.
Product recommendations
Model:
QT12-20-220 2BD, QT16-20-300 2BD, QT24-20-460 2BD
QT30-20-580 2BD, QT38-20-740 2BD, QT46-20-900 2BD
QT54-20-1060 2BD, QT60-20-1180 2BD, QT68-20-1340 2BD
QT76-20-1500 2BD, QT84-20-1660 2BD,QT90-20-1780 2BD
FAQ
Q: How to troubleshoot unstable safety light curtains?
A:
Safety light curtains are widely used in various industries to ensure safety in production processes. During this process, it is crucial to perform regular analysis, inspection, and maintenance of safety light curtains to ensure their effective use. In the case of encountering unstable factors, here's what you can do to troubleshoot:
Factors causing instability in safety light curtains and their corresponding solutions:
1. Electromagnetic interference: Ensure proper grounding and separate the signal lines from the power lines of the light curtain.
2. Unstable power supply: Replace with a dedicated and stable power supply.
3. Interference from sunlight, lasers, or arcs: Choose Epson's light curtains with anti-sunlight capabilities.
4. Lens obstructed by dust: Clean the lens to remove dust and restore proper light reception.
5. Instability due to vibration: Realign the light curtain and use vibration-resistant brackets.
6. Insufficient distance between transmitter and receiver: If the actual required distance exceeds the light curtain's maximum range, replace it with a light curtain that has a longer range.
7. Sufficient distance but misalignment causing insufficient light reception: Readjust the angle of the light curtain for proper alignment.
8. Normal operation during the day but instability at night: Insufficient light reception; choose a light curtain with a larger detection range.
9. Interference between adjacent light curtains: Rearrange the positions of the transmitters and receivers or consider using Dadi's anti-interference safety light curtains.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.