For Leuze MLC 510 / 520 Series Light Curtain Sensor Replacement 14 mm Resolution Finger Protection 150 mm to 1800 mm Protection Height
- Model
- MLC 510 / 520 Series | MLC500T14-150G, MLC520R14-150G, MLC500T14-300G, MLC520R14-300G, MLC500T14-450G, MLC520R14-450G, MLC500T14-600G, MLC520R14-600G, MLC500T14-750G, MLC520R14-750G, MLC500T14-900G, MLC520R14-900G, MLC500T14-1050G, MLC520R14-1050G, MLC500T14-1200G, MLC520R14-1200G, MLC500T14-1350G, MLC520R14-1350G, MLC500T14-1500G, MLC520R14-1500G, MLC500T14-1650G, MLC520R14-1650G, MLC500T14-1800G, MLC520R14-1800G
Item specifics
- Series:
- MLC 510 / 520 Series
- Resolution:
- 14 mm
- Scanning range:
- 0 - 6 m
- Protective field height:
- 150 - 1800 mm
- 2 Safety outputs (OSSD):
- 2 PNP
- Response time:
- 4 - 38 ms
- Connection type:
- M12
- Security level:
- PLe4
Review
Description
For Leuze MLC 510 / 520 Series Light Curtain Sensor Replacement 14 mm Resolution Finger Protection 150 mm to 1800 mm Protection Height Parameter
Brand | Transmitter | Receiver | DADISICK |
|
Models | MLC500T14-150G | MLC520R14-150G | QM16-10-150 2BB | |
MLC500T14-300G | MLC520R14-300G | QM30-10-290 2BB | ||
MLC500T14-450G | MLC520R14-450G | QM46-10-450 2BB | ||
MLC500T14-600G | MLC520R14-600G | QM60-10-590 2BB | ||
MLC500T14-750G | MLC520R14-750G | QM74-10-730 2BB | ||
MLC500T14-900G | MLC520R14-900G | QM90-10-890 2BB | ||
MLC500T14-1050G | MLC520R14-1050G | QM104-10-1030 2BB | ||
MLC500T14-1200G | MLC520R14-1200G | QM120-10-1190 2BB | ||
MLC500T14-1350G | MLC520R14-1350G | QM134-10-1330 2BB | ||
MLC500T14-1500G | MLC520R14-1500G | QM150-10-1490 2BB | ||
MLC500T14-1650G | MLC520R14-1650G | QM164-10-1630 2BB | ||
MLC500T14-1800G | MLC520R14-1800G | QM180-10-1790 2BB | ||
Beam spacing | 14 mm | 10 mm | ||
Protected altitude | 150 mm, 300 mm, 450 mm, 600 mm, 750 mm, 900 mm, 1050 mm, 1200 mm, 1350 mm, 1500 mm, 1650 mm, 1800 mm | 150 mm, 290 mm, 450 mm, 590 mm, 730 mm, 890 mm, 1030 mm, 1190 mm, 1330 mm, 1490 mm, 1630 mm, 1790 mm | ||
Scanning range | 0 - 6 m | 0.3 - 6 m | ||
Response time | 4 - 38 ms | ≤15 ms | ||
Output method | 2 PNP | 2 PNP | ||
Reliability and durability | IP65 | IP65 | ||
Connector | M12 | M16 | ||
Housing cross-section | 35.4 mm x 29 mm | 36 mm x 36 mm | ||
Safety Certificate | KCs, TÜV Süd, c TÜV NRTL US, c UL US, PLe4 | TUV, UL, CE, RoSH, GB | ||
We are able to reproduce the specific connection configuration of each brand with high level of accuracy. |
Product model display instructions
The brands and specifications shown on this page are for product selection only. Our safety light curtain is a safety part made by DADISICK, not official brand Leuze's products. DAIDSICK offer replacement for official brand products. We are not the owner of the brands. If you need to buy official brand products, please contact the brand official representative.
Product recommendations
Model:
QM16-10-150 2BB, QM30-10-290 2BB, QM46-10-450 2BB
QM60-10-590 2BB, QM74-10-730 2BB, QM90-10-890 2BB
QM104-10-1030 2BB, QM120-10-1190 2BB, QM134-10-1330 2BB
QM150-10-1490 2BB, QM164-10-1630 2BB, QM180-10-1790 2BB
FAQ
Q:what is the difference between a level 2 safety light curtain and lever 4 safety light curtain ?
A:
Level 2 safety light curtains have the following characteristics:
1. Low cost: Level 2 safety light curtains are generally affordable compared to higher level light curtains.
2. Performance: Level 2 light curtains typically utilize a single CPU processor for their operation.
3. Dual safety channel outputs: They provide two separate output channels for enhanced safety redundancy and reliability4. Self-diagnosis or external periodic testing: Level 2 light curtains can perform self-diagnosis or be externally tested at regular intervals to check for any faults or malfunctions.
5. Fault exclusion method for safety performance: These light curtains employ fault exclusion techniques to ensure that they maintain their safety performance even in the presence of potential faults or failures.
6. Application range: Level 2 safety light curtains are suitable for use in situations or machines where the risk of injury is moderate or low. They are commonly used in automated production equipment, material handling devices, and similar applications.
Level 4 safety light curtains have the following characteristics:
1. Higher cost: Level 4 safety light curtains are generally more expensive compared to lower level light curtains due to their advanced features and performance.
2. Performance: Level 4 light curtains typically utilize dual CPU processors for increased processing power and reliability.
3. Dual safety channel outputs: Similar to level 2 light curtains, they provide two separate output channels for enhanced safety redundancy and reliability.
4. More reliable control, less susceptible to interference: Level 4 light curtains are designed to be less affected by ambient light or other sources of interference, ensuring more reliable operation.
5. Self-diagnosis and advanced fault detection: They incorporate self-diagnosis capabilities for fault checking and may have additional features such as higher-level redundant fault cross-checking.
6. Application range: Level 4 safety light curtains are suitable for use in high-risk environments or machines where the potential for serious injury is greater. They provide effective protection for dangerous areas.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.