- Model
- TZ Series | TZ1LB024MVAB-C2159, TZ1LE024BHA10VAB-C2401, TZ1LE024BHA10VAB-C2402, TZ1LE024MVAB, TZ1LE024MVAB-C1623, TZ1LE024MVAB-C1684, TZ1LE024MVAB-C1828, TZ1LE024MVAB-C2082, TZ1LE024MVAB-C2087, TZ1LE024MVAB-R, TZ1LE024MVAB-RC2100, TZ1LE024RC18VAB, TZ1LE024RC18VAB-092998, TZ1LE024RC18VAB-093862, TZ1LE024RC18VAB-C1803, TZ1LE024RC18VAB-C1823, TZ1LE024RC18VAB-C1826, TZ1LE024RC18VAB-C1828, TZ1LE024RC18VAB-C1937, TZ1LE024RC18VAB-C2123, TZ1LE024RC18VAB-C2140, TZ1LE024SR11VAB-C1933, TZ1LE110MVAB, TZ1LE110MVAB-C1828, TZ1LE110MVAB-C2082, TZ1LE220MVAB, TZ1RB024MVAB-C2159, TZ1RE024BHA10VAB-C2401, TZ1RE024BHA10VAB-C2402, TZ1RE024MVAB, TZ1RE024MVAB-C1623, TZ1RE024MVAB-C1684, TZ1RE024MVAB-C1828, TZ1RE024MVAB-C2082, TZ1RE024MVAB-C2087, TZ1RE024MVAB-R, TZ1RE024MVAB-RC2100, TZ1RE024RC18VAB, TZ1RE024RC18VAB-092999, TZ1RE024RC18VAB-093863, TZ1RE024RC18VAB-C1803, TZ1RE024RC18VAB-C1823, TZ1RE024RC18VAB-C1826, TZ1RE024RC18VAB-C1828, TZ1RE024RC18VAB-C1937, TZ1RE024RC18VAB-C2123, TZ1RE024RC18VAB-C2140, TZ1RE024SR11VAB-C1933, TZ1RE110MVAB, TZ1RE110MVAB-C1623, TZ1RE110MVAB-C1828, TZ1RE110MVAB-C2082, TZ1RE220MVAB, TZ1LE024BHA-C1902, TZ1LE024BHA-C1903, TZ1LE024BHA-C2399, TZ1LE024BHAVFG-RC1924, TZ1LE024BHAVFG-RC1971, TZ1LE024MVFG-RC1925, TZ1RE024BHA-C1902, TZ1RE024BHA-C1903, TZ1RE024BHA-C2399, TZ1RE024BHAVFG-RC1924, TZ1RE024BHAVFG-RC1971, TZ1RE024MVFG-RC1925
Item specifics
- Series:
- TZ Series
- Locking principle:
- Mechanical Lock, Solenoid Release
- Number of contacts:
- 4
- Locking force:
- 1500 N
- Material:
- Anodized die-cast alloy
- Connection:
- M20 or Plug connector BHA10/BHA12/RC18/SR11
- Security level:
- IP65 / IP67
- Certifications:
- EAC, GL, UL, CCC, DGUV
Review
Description
TZ Series with Door and Lock monitoring 4 Contacts Mechanical Lock Solenoid Release Safety switch Replacement Parameter
Brand | From network | DADISICK |
|
Models | TZ1LB024MVAB-C2159 | TZ1RE024MVAB-C2082 |
OX-W2 series |
TZ1LE024BHA10VAB-C2401 | TZ1RE024MVAB-C2087 | ||
TZ1LE024BHA10VAB-C2402 | TZ1RE024MVAB-R | ||
TZ1LE024MVAB | TZ1RE024MVAB-RC2100 | ||
TZ1LE024MVAB-C1623 | TZ1RE024RC18VAB | ||
TZ1LE024MVAB-C1684 | TZ1RE024RC18VAB-092999 | ||
TZ1LE024MVAB-C1828 | TZ1RE024RC18VAB-093863 | ||
TZ1LE024MVAB-C2082 | TZ1RE024RC18VAB-C1803 | ||
TZ1LE024MVAB-C2087 | TZ1RE024RC18VAB-C1823 | ||
TZ1LE024MVAB-R | TZ1RE024RC18VAB-C1826 | ||
TZ1LE024MVAB-RC2100 | TZ1RE024RC18VAB-C1828 | ||
TZ1LE024RC18VAB | TZ1RE024RC18VAB-C1937 | ||
TZ1LE024RC18VAB-092998 | TZ1RE024RC18VAB-C2123 | ||
TZ1LE024RC18VAB-093862 | TZ1RE024RC18VAB-C2140 | ||
TZ1LE024RC18VAB-C1803 | TZ1RE024SR11VAB-C1933 | ||
TZ1LE024RC18VAB-C1823 | TZ1RE110MVAB | ||
TZ1LE024RC18VAB-C1826 | TZ1RE110MVAB-C1623 | ||
TZ1LE024RC18VAB-C1828 | TZ1RE110MVAB-C1828 | ||
TZ1LE024RC18VAB-C1937 | TZ1RE110MVAB-C2082 | ||
TZ1LE024RC18VAB-C2123 | TZ1RE220MVAB | ||
TZ1LE024RC18VAB-C2140 | TZ1LE024BHA-C1902 | ||
TZ1LE024SR11VAB-C1933 | TZ1LE024BHA-C1903 | ||
TZ1LE110MVAB | TZ1LE024BHA-C2399 | ||
TZ1LE110MVAB-C1828 | TZ1LE024BHAVFG-RC1924 | ||
TZ1LE110MVAB-C2082 | TZ1LE024BHAVFG-RC1971 | ||
TZ1LE220MVAB | TZ1LE024MVFG-RC1925 | ||
TZ1RB024MVAB-C2159 | TZ1RE024BHA-C1902 | ||
TZ1RE024BHA10VAB-C2401 | TZ1RE024BHA-C1903 | ||
TZ1RE024BHA10VAB-C2402 | TZ1RE024BHA-C2399 | ||
TZ1RE024MVAB | TZ1RE024BHAVFG-RC1924 | ||
TZ1RE024MVAB-C1623 | TZ1RE024BHAVFG-RC1971 | ||
TZ1RE024MVAB-C1684 | TZ1RE024MVFG-RC1925 | ||
TZ1RE024MVAB-C1828 | — | ||
Sensor principle | Closed-circuit current principle | Electro-mechanical | |
Locking principle | Mechanical Lock, Solenoid Release | Mechanical Lock, Solenoid Release | |
Number of contacts | 4 | 4 | |
Locking force | 1500 N | 1300 N | |
Approach speed | 20 m/min | 0.05 - 0.5 m/s | |
Actuation frequency | max. 1200 1/h | Up to 20 operations/min | |
Material | Anodized die-cast alloy | Metal, PA66 flame retardant | |
Connector | M20 or Plug connector BHA10/BHA12/RC18/SR11 | M20 or 1.5 m cable | |
Power consumption | 10 W | 4.8 W | |
Switching voltage | 24 V DC | 24 V DC | |
Rated operating current (voltage) | AC-15: 4 A / 230 V
DC-13: 4 A / 24 V | AC-15: 3 A / 240 V
DC-13: 2.3 A / 30 V | |
Rated impulse withstand voltage (Uimp) | 1.5 kV, 1.5 kV, 2.5kV | 2.5 kV | |
Enclosure rating | IP65 / IP67 | IP67 | |
Ambient operating temperature | -25 to 80℃ | -20℃ to 60℃ | |
We are able to reproduce the specific connection configuration of each brand with high level of accuracy. |
Product model display instructions
The product models displayed on this page are only used to describe and compare the characteristics, specifications, and performance of different products. These models do not represent recommendations or associations for any specific brand or company. When users choose products, please understand and compare the detailed information of each brand's products on your own.
Product recommendations
Safety switches OX-W2 series
Mechanical Lock, Solenoid Release Model:
OX-W2-CO/CO-GC-J, OX-W2-CO/2C-GC-J, OX-W2-2C/CO-GC-J,
OX-W2-2C/2C-GC-J, OX-W2-C20/C-GC-J, OX-W2-3C/C-GC-J,
OX-W2-2CO/C-GC-J, OX-W2-C/3C-GC-J, OX-W2-C/C20-GC-J,
OX-W2-C/2CO-GC-J, OX-W2-0/3C-GC-J, OX-W2-0/2CO-GC-J,
OX-W2-2C/20-GC-J, OX-W2-20/2C-GC-J
FAQ
What are the applications of safety switches?
Safety switches are widely used in industrial automation, manufacturing, logistics systems, medical equipment, and other scenarios, especially where operational safety is crucial.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.