- Model
- NZ Series | NZ1RS-511-M, NZ1RS-511-MC1588, NZ1RS-511L060-M, NZ1RS-511L060GE-M, NZ1RS-528-M, NZ1RS-528-MC1588, NZ1RS-528L060-M, NZ1RS-528L220-M, NZ1RS-538-M, NZ1RS-538L060-M, NZ1RS-538L060GE-M, NZ1RS-3131-M, NZ1RS-3131-M-EX, NZ1RS-3131-MC2222, NZ1RS-2131-9C-GMMF, NZ1RS-2131-M, NZ1RS-2121-M, NZ2RS-511, NZ2RS-511L060, NZ2RS-511L060C1630, NZ2RS-511SVM5, NZ2RS-511SVM5L060GE, NZ2RS-511SVM5L060GEC2273, NZ2RS-528, NZ2RS-528L060, NZ2RS-528SVM5, NZ2RS-538, NZ2RS-538L060, NZ2RS-538SVM5, NZ2RS-3131, NZ2RS-3131-9C-GMMF, NZ2RS-2131, NZ2RS-2131L024GEC2300, NZ2RS-2121, NZ1WO-511-M, NZ1WO-511L060-M, NZ1WO-528-M, NZ1WO-528L060-M, NZ1WO-538-M, NZ1WO-538L060-M, NZ1WO-3131-M, NZ1WO-2131-M, NZ2WO-511, NZ2WO-511L060, NZ2WO-511L060C1630, NZ2WO-511SVM5, NZ2WO-511SVM5L060GE, NZ2WO-511SVM5L060GEC2273, NZ2WO-528L060, NZ2WO-528SVM5, NZ2WO-538L060, NZ2WO-538SVM5, NZ2WO-3131, NZ2WO-2131, NZ2WO-2121
Item specifics
- Series:
- NZ Series
- Locking principle:
- Plunger, Lever arm or Switch head
- Number of contacts:
- 2 or 4
- Actuating force:
- min. 15 N
- Material:
- Anodized die-cast alloy
- Connection:
- M20 or Plug connector M12/MR9/SR11/SR6
- Security level:
- IP67
- Certifications:
- EAC, GL, UL
Review
Description
NZ Series 2 or 4 Contacts Position Safety Switches Replacement Parameter
Brand | From network | DADISICK |
|
Models | NZ1RS-511-M | NZ2RS-538SVM5 |
OX-D2/OX-D3 series |
NZ1RS-511-MC1588 | NZ2RS-3131 | ||
NZ1RS-511L060-M | NZ2RS-3131-9C-GMMF | ||
NZ1RS-511L060GE-M | NZ2RS-2131 | ||
NZ1RS-528-M | NZ2RS-2131L024GEC2300 | ||
NZ1RS-528-MC1588 | NZ2RS-2121 | ||
NZ1RS-528L060-M | NZ1WO-511-M | ||
NZ1RS-528L220-M | NZ1WO-511L060-M | ||
NZ1RS-538-M | NZ1WO-528-M | ||
NZ1RS-538L060-M | NZ1WO-528L060-M | ||
NZ1RS-538L060GE-M | NZ1WO-538-M | ||
NZ1RS-3131-M | NZ1WO-538L060-M | ||
NZ1RS-3131-M-EX | NZ1WO-3131-M | ||
NZ1RS-3131-MC2222 | NZ1WO-2131-M | ||
NZ1RS-2131-9C-GMMF | NZ2WO-511 | ||
NZ1RS-2131-M | NZ2WO-511L060 | ||
NZ1RS-2121-M | NZ2WO-511L060C1630 | ||
NZ2RS-511 | NZ2WO-511SVM5 | ||
NZ2RS-511L060 | NZ2WO-511SVM5L060GE | ||
NZ2RS-511L060C1630 | NZ2WO-511SVM5L060GEC2273 | ||
NZ2RS-511SVM5 | NZ2WO-528L060 | ||
NZ2RS-511SVM5L060GE | NZ2WO-528SVM5 | ||
NZ2RS-511SVM5L060GEC2273 | NZ2WO-538L060 | ||
NZ2RS-528 | NZ2WO-538SVM5 | ||
NZ2RS-528L060 | NZ2WO-3131 | ||
NZ2RS-528SVM5 | NZ2WO-2131 | ||
NZ2RS-538 | NZ2WO-2121 | ||
NZ2RS-538L060 | — | ||
Sensor principle | Electro-mechanical | Electro-mechanical | |
Locking principle | Plunger, Lever arm or Switch head | Operation Key | |
Number of contacts | 2 or 4 | 2 or 3 | |
Direct Opening Force | — | ≥ 60 N | |
Approach speed | 0.1-20m/min, 0.1-10m/min | 0.05 - 0.5 m/s | |
Actuation frequency | 7000/h | Up to 20 operations/min | |
Material | Anodized die-cast alloy | Resin, PA66 flame retardant | |
Connector | M20 or Plug connector M12/MR9/SR11/SR6 | M20 | |
Power consumption | — | — | |
Rated insulation voltage (Ui) | 250 V | 400 V | |
Rated operating current (voltage) | Connection, cable entry M20 x 1.5, Parameter AC-12: 10 A / 230 V
AC-15: 6 A / 230 V OR 4 A / 230 V
DC-13: 6 A / 24 V OR 4 A / 24 V | AC-15: 2 A / AC 400 V | |
Rated impulse withstand voltage (Uimp) | 1.5 kV, 1.5 kV, 2.5 kV | 4 kV | |
Enclosure rating | IP65 / IP67 | IP67 | |
Ambient operating temperature | -25 to 80℃ | -20℃ to 60℃ | |
We are able to reproduce the specific connection configuration of each brand with high level of accuracy. |
Product model display instructions
The product models displayed on this page are only used to describe and compare the characteristics, specifications, and performance of different products. These models do not represent recommendations or associations for any specific brand or company. When users choose products, please understand and compare the detailed information of each brand's products on your own.
Product recommendations
FAQ
What is the safety level of a Safety Interlock Switch?
Safety levels are usually defined by international standards (such as ISO 13849-1 or IEC 62061) and describe the performance level (PL) or safety integrity level (SIL) of the safety system. Selecting the appropriate safety level ensures that the system meets the required safety performance.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.