For Schmersal SLC440AS Series 30 mm Resolution 10 m Sensing Distance 170 mm to 1770 mm Protective Height Safety Light Curtain Replacement
- Model
- SLC440AS Series | SLC440AS-ER-0170-30, SLC440AS-ER-0250-30, SLC440AS-ER-0330-30, SLC440AS-ER-0410-30, SLC440AS-ER-0490-30, SLC440AS-ER-0570-30, SLC440AS-ER-0650-30, SLC440AS-ER-0730-30, SLC440AS-ER-0810-30, SLC440AS-ER-0890-30, SLC440AS-ER-0970-30, SLC440AS-ER-1050-30, SLC440AS-ER-1130-30, SLC440AS-ER-1210-30, SLC440AS-ER-1290-30, SLC440AS-ER-1370-30, SLC440AS-ER-1450-30, SLC440AS-ER-1530-30, SLC440AS-ER-1610-30, SLC440AS-ER-1690-30, SLC440AS-ER-1770-30
Item specifics
- Series:
- SLC440AS Series
- Resolution:
- 30 mm
- Scanning range:
- 0.3 - 10 m
- Protective field height:
- 170 - 1770 mm
- 2 Safety outputs (OSSD):
- 2 PNP
- Response time:
- 13 - 23 ms
- Connection type:
- M12
- security level:
- PLe4
Review
Description
For Schmersal SLC440AS Series 30 mm Resolution 10 m Sensing Distance 170 mm to 1770 mm Protective Height Safety Light Curtain Replacement Parameter
Brand | From network | DADISICK |
|
Models
|
SLC440AS-ER-0170-30 | QT06-40-200 2BC |
|
SLC440AS-ER-0250-30 |
QT08-40-280 2BC | ||
SLC440AS-ER-0330-30 | QT10-40-360 2BC |
||
SLC440AS-ER-0410-30 | QT12-40-440 2BC | ||
SLC440AS-ER-0490-30 | QT14-40-520 2BC | ||
SLC440AS-ER-0570-30 | QT16-40-600 2BC | ||
SLC440AS-ER-0650-30 | QT18-40-680 2BC | ||
SLC440AS-ER-0730-30 | QT20-40-760 2BC | ||
SLC440AS-ER-0810-30 | QT22-40-840 2BC | ||
SLC440AS-ER-0890-30 | QT24-40-920 2BC | ||
SLC440AS-ER-0970-30 | QT26-40-1000 2BC | ||
SLC440AS-ER-1050-30 | QT28-40-1080 2BC | ||
SLC440AS-ER-1130-30 | QT30-40-1160 2BC | ||
SLC440AS-ER-1210-30 | QT32-40-1240 2BC | ||
SLC440AS-ER-1290-30 | QT34-40-1320 2BC | ||
SLC440AS-ER-1370-30 | QT36-40-1400 2BC | ||
SLC440AS-ER-1450-30 | QT38-40-1480 2BC | ||
SLC440AS-ER-1530-30 | QT40-40-1560 2BC | ||
SLC440AS-ER-1610-30 | QT42-40-1640 2BC | ||
SLC440AS-ER-1690-30 | QT44-40-1720 2BC | ||
SLC440AS-ER-1770-30 | QT46-40-1800 2BC | ||
Beam spacing | 30 mm | 40 mm | |
Protected altitude | 170 mm, 250 mm, 330 mm, 410 mm, 490 mm, 570 mm, 650 mm, 730 mm, 810 mm, 890 mm, 970 mm, 1050 mm, 1130 mm, 1210 mm, 1290 mm, 1370 mm, 1450 mm, 1530 mm, 1610 mm, 1690 mm, 1770 mm | 200 mm, 280 mm, 360 mm, 440 mm, 520 mm, 600 mm, 680 mm, 760 mm, 840 mm, 920 mm, 1000 mm, 1080 mm, 1160 mm, 1240 mm, 1320 mm, 1400 mm, 1480 mm, 1560 mm, 1640 mm, 1720 mm, 1800 mm | |
Scanning range | 0.3 - 10 m | 0.3 - 10 m | |
Response time | 13 ms - 23 ms | ≤15 ms | |
Output method | 2 PNP | 2 PNP | |
Reliability and durability | IP67 | IP65 | |
Connector | M12 | M16 | |
Housing cross-section | 33 mm x 27.5 mm | 51 mm x 35 mm | |
Safety Certificate | TÜV, UL, ASI | TÜV, UL, CE, RoHS, GB | |
We are able to reproduce the specific connection configuration of each brand with high level of accuracy. |
Product model display instructions
The brands and specifications shown on this page are for product selection only. Our safety light curtain is a safety part made by DADISICK, not official brand Schmersal's products. DAIDSICK offer replacement for official brand products. We are not the owner of the brands. If you need to buy official brand products, please contact the brand official representative.
Product recommendations
Model:
QT06-40-200 2BC, QT08-40-280 2BC, QT10-40-360 2BC
QT12-40-440 2BC, QT14-40-520 2BC, QT16-40-600 2BC
QT18-40-680 2BC, QT20-40-760 2BC, QT22-40-840 2BC
QT24-40-920 2BC, QT26-40-1000 2BC, QT28-40-1080 2BC
QT30-40-1160 2BC, QT32-40-1240 2BC, QT34-40-1320 2BC
QT36-40-1400 2BC, QT38-40-1480 2BC, QT40-40-1560 2BC
QT42-40-1640 2BC, QT44-40-1720 2BC, QT46-40-1800 2BC
FAQ
Q:How to determine if a safety light curtain is working properly?
A:
Safety light curtains are also known as safety light screens, safety light curtain sensors, infrared safety light curtains, photoelectric protectors, infrared photoelectric protectors, punch press photoelectric protection devices, etc.
How to determine if a safety light curtain is in working mode?
Many customers may have doubts when using a light curtain for the first time, wondering if it is installed correctly and if it is in normal working mode.
Because the purpose of a safety light curtain is to protect personal safety, it must be taken seriously. So how can we determine if a safety light curtain is in working mode?
When the safety light curtain is powered on, the emitter will flash three times and then remain on, indicating that it has entered the working mode. The receiver will have red and green lights flashing three times when powered on, indicating that it has also entered the working mode.
What are the conditions for the safety light curtain to be working properly?
When the emitter and receiver are in working condition, the emitter's red light remains on, and the receiver's green light is illuminated. When the light curtain is obstructed, there is no change in the emitter's indicator light, but the receiver's light changes from green to red, and the digital display shows the number of blocked light beams. When there is no obstruction, the receiver returns to its normal state with a constant green light.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.