For Schmersal SLC440AS Series 14 mm Resolution 7 m Sensing Distance 170 mm to 1450 mm Protective Height Safety Light Curtain Replacement
- Model
- SLC440AS Series | SLC440AS-ER-0170-14, SLC440AS-ER-0250-14, SLC440AS-ER-0330-1, SLC440AS-ER-0410-14, SLC440AS-ER-0490-14, SLC440AS-ER-0570-14, SLC440AS-ER-0650-14, SLC440AS-ER-0730-14, SLC440AS-ER-0810-14, SLC440AS-ER-0890-14, SLC440AS-ER-0970-14, SLC440AS-ER-1050-14, SLC440AS-ER-1130-14, SLC440AS-ER-1210-14, SLC440AS-ER-1290-14, SLC440AS-ER-1370-14, SLC440AS-ER-1450-14
Item specifics
- Series
- SLC440AS Series
- Resolution:
- 14 mm
- Scanning range:
- 0.3 - 7 m
- Protective field height:
- 170 - 1450 mm
- 2 Safety outputs (OSSD):
- 2 PNP
- Response time:
- 13 - 23 ms
- Connection type:
- M12
- Security level:
- PLe4
Review
Description
For Schmersal SLC440AS Series 14 mm Resolution 7 m Sensing Distance 170 mm to 1450 mm Protective Height Safety Light Curtain Replacement Parameter
Brand | From network | DADISICK |
|
Models
|
SLC440AS-ER-0170-14 | QM18-10-170 2BC |
|
SLC440AS-ER-0250-14 |
QM26-10-250 2BC | ||
SLC440AS-ER-0330-14 | QM34-10-330 2BC |
||
SLC440AS-ER-0410-14 | QM42-10-410 2BC | ||
SLC440AS-ER-0490-14 | QM50-10-490 2BC | ||
SLC440AS-ER-0570-14 | QM58-10-570 2BC | ||
SLC440AS-ER-0650-14 | QM66-10-650 2BC | ||
SLC440AS-ER-0730-14 | QM74-10-730 2BC | ||
SLC440AS-ER-0810-14 | QM82-10-810 2BC | ||
SLC440AS-ER-0890-14 | QM90-10-890 2BC | ||
SLC440AS-ER-0970-14 | QM98-10-970 2BC | ||
SLC440AS-ER-1050-14 | QM106-10-1050 2BC | ||
SLC440AS-ER-1130-14 | QM114-10-1130 2BC | ||
SLC440AS-ER-1210-14 | QM122-10-1210 2BC | ||
SLC440AS-ER-1290-14 | QM130-10-1290 2BC | ||
SLC440AS-ER-1370-14 | QM138-10-1370 2BC | ||
SLC440AS-ER-1450-14 | QM146-10-1450 2BC | ||
Beam spacing | 14 mm | 10 mm | |
Protected altitude | 170 mm, 250 mm, 330 mm, 410 mm, 490 mm, 570 mm, 650 mm, 730 mm, 810 mm, 890 mm, 970 mm, 1050 mm, 1130 mm, 1210 mm, 1290 mm, 1370 mm, 1450 mm | 170 mm, 250 mm, 330 mm, 410 mm, 490 mm, 570 mm, 650 mm, 730 mm, 810 mm, 890 mm, 970 mm, 1050 mm, 1130 mm, 1210 mm, 1290 mm, 1370 mm, 1450 mm | |
Scanning range | 0.3 - 7 m | 0.3 - 10 m | |
Response time | 13 ms - 23 ms | ≤15 ms | |
Output method | 2 PNP | 2 PNP | |
Reliability and durability | IP67 | IP65 | |
Connector | M12 | M12 | |
Housing cross-section | 33 mm x 27.8 mm | 36 mm x 36 mm | |
Safety Certificate | TÜV, UL, ASI | TÜV, UL, CE, RoHS, GB | |
We are able to reproduce the specific connection configuration of each brand with high level of accuracy. |
Product model display instructions
The brands and specifications shown on this page are for product selection only. Our safety light curtain is a safety part made by DADISICK, not official brand Schmersal's products. DAIDSICK offer replacement for official brand products. We are not the owner of the brands. If you need to buy official brand products, please contact the brand official representative.
Product recommendations
Model:
QM18-10-170 2BC, QM26-10-250 2BC, QM34-10-330 2BC
QM42-10-410 2BC, QM50-10-490 2BC, QM58-10-570 2BC
QM66-10-650 2BC, QM74-10-730 2BC, QM82-10-810 2BC
QM90-10-890 2BC, QM98-10-970 2BC, QM106-10-1050 2BC
QM114-10-1130 2BC, QM122-10-1210 2BC, QM130-10-1290 2BC
QM138-10-1370 2BC, QM146-10-1450 2BC
FAQ
Q:How to maintain and service a safety light curtain? - DADISICK Da Dishi Ke
A:
Good maintenance and care of a safety light curtain are crucial as they directly impact its lifespan and can even affect its safety functions. Therefore, proper maintenance is essential. Here are a few tips based on experience:
Experience 1: Each grating should be regularly inspected and maintained, with dedicated personnel responsible for their care.
Experience 2: Before starting work each day, it is important to check if the safety grating is powered on and functioning properly before operating the machine.
Experience 3: Develop the habit of regularly cleaning the grating, especially the filter plate, to avoid oil stains and dust. If possible, it is recommended to provide a protective cover for the grating.
Experience 4: When replacing or adjusting the mold on the machine, make sure to adjust the height and safety distance of the grating to the appropriate position after completing the task.
Experience 5: Avoid stacking objects near the installation area of the grating to prevent accidental damage.
Experience 6: It is advisable to have a professional inspection or maintenance of the grating performed annually. If any malfunctions occur, do not attempt to repair it yourself, but rather seek the assistance of a professional technician.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.