For Pilz PSENopt Series 14 mm Resolution 6 m Sensing Distance 150 mm to 1200 mm Protective Height Slimline Type 4 Light Curtain with Finger Protection Replacement
- Model
- PSENopt Series | PSEN op4F-SL-14-015/1, PSEN op4F-SL-14-021/1, PSEN op4F-SL-14-030/1, PSEN op4F-SL-14-036/1, PSEN op4F-SL-14-042/1, PSEN op4F-SL-14-045/1, PSEN op4F-SL-14-048/1, PSEN op4F-SL-14-054/1, PSEN op4F-SL-14-060/1, PSEN op4F-SL-14-066/1, PSEN op4F-SL-14-072/1, PSEN op4F-SL-14-075/1, PSEN op4F-SL-14-078/1, PSEN op4F-SL-14-084/1, PSEN op4F-SL-14-090/1, PSEN op4F-SL-14-096/1, PSEN op4F-SL-14-102/1, PSEN op4F-SL-14-105/1, PSEN op4F-SL-14-108/1, PSEN op4F-SL-14-114/1, PSEN op4F-SL-14-120/1
Item specifics
- Series
- PSENopt Series
- Resolution:
- 14 mm
- Scanning range:
- 0.2 - 6 m
- Protective field height:
- 150 - 1200 mm
- 2 Safety outputs (OSSD):
- 2 PNP
- Response time:
- 7 - 17 ms
- Connection type:
- M12
- Security level:
- PLe4
Review
Description
For Pilz PSENopt Series 14 mm Resolution 6 m Sensing Distance 150 mm to 1200 mm Protective Height Slimline Type 4 Light Curtain with Finger Protection Replacement Parameter
Brand | From network | DADISICK |
|
Models
|
PSEN op4F-SL-14-015/1 | QBT16-10-150 2BA |
|
PSEN op4F-SL-14-021/1 |
QBT22-10-210 2BA | ||
PSEN op4F-SL-14-030/1 | QBT30-10-290 2BA |
||
PSEN op4F-SL-14-036/1 | QBT36-10-350 2BA | ||
PSEN op4F-SL-14-042/1 | QBT42-10-410 2BA | ||
PSEN op4F-SL-14-045/1 | QBT46-10-450 2BA | ||
PSEN op4F-SL-14-048/1 | QBT48-10-470 2BA | ||
PSEN op4F-SL-14-054/1 | QBT54-10-530 2BA | ||
PSEN op4F-SL-14-060/1 | QBT60-10-590 2BA | ||
PSEN op4F-SL-14-066/1 | QBT66-10-650 2BA | ||
PSEN op4F-SL-14-072/1 | QBT72-10-710 2BA | ||
PSEN op4F-SL-14-075/1 | QBT76-10-750 2BA | ||
PSEN op4F-SL-14-078/1 | QBT78-10-770 2BA | ||
PSEN op4F-SL-14-084/1 | QBT84-10-830 2BA | ||
PSEN op4F-SL-14-090/1 | QBT90-10-890 2BA | ||
PSEN op4F-SL-14-096/1 | QBT96-10-950 2BA | ||
PSEN op4F-SL-14-102/1 | QBT102-10-1010 2BA | ||
PSEN op4F-SL-14-105/1 | QBT106-10-1050 2BA | ||
PSEN op4F-SL-14-108/1 | QBT108-10-1070 2BA | ||
PSEN op4F-SL-14-114/1 | QBT114-10-1130 2BA | ||
PSEN op4F-SL-14-120/1 | QBT120-10-1190 2BA | ||
Beam spacing | 14 mm | 10 mm | |
Protected altitude | 150 mm, 210 mm, 300 mm, 360 mm, 420 mm, 450 mm, 480 mm, 540 mm, 600 mm, 660 mm, 720 mm, 750 mm, 780 mm, 840 mm, 900 mmm, 960 mm, 1020 mm, 1050 mm, 1080 mm, 1140 mm, 1200 mm | 150 mm, 210 mm, 290 mm, 350 mm, 410 mm, 450 mm, 470 mm, 530 mm, 590 mm, 650 mm, 710 mm, 750 mm, 770 mm, 830 mm, 890 mm, 950 mm, 1010 mm, 1050 mm, 1070 mm, 1130 mm, 1190 mm | |
Scanning range | 0.2 - 6 m | 0.3 - 3m | |
Response time | 7 ms - 17 ms | ≤15 ms | |
Output method | 2 PNP | 2 PNP | |
Reliability and durability | IP65 | IP65 | |
Connector | M12 | M8 | |
Housing cross-section | 32.6 mm x 15.4 mm | 15 mm x 30 mm | |
Safety Certificate | CE, cULus, TÜV | TÜV, UL, CE, RoHS, GB | |
We are able to reproduce the specific connection configuration of each brand with high level of accuracy. |
Product model display instructions
The brands and specifications shown on this page are for product selection only. Our safety light curtain is a safety part made by DADISICK, not official brand Pilz's products. DAIDSICK offer replacement for official brand products. We are not the owner of the brands. If you need to buy official brand products, please contact the brand official representative.
Product recommendations
Model:
QBT16-10-150 2BA, QBT22-10-210 2BA, QBT30-10-290 2BA
QBT36-10-350 2BA, QBT42-10-410 2BA, QBT46-10-450 2BA
QBT48-10-470 2BA, QBT54-10-530 2BA, QBT60-10-590 2BA
QBT66-10-650 2BA, QBT72-10-710 2BA, QBT76-10-750 2BA
QBT78-10-770 2BA, QBT84-10-830 2BA, QBT90-10-890 2BA
QBT96-10-950 2BA, QBT102-10-1010 2BA, QBT106-10-1050 2BA
QBT108-10-1070 2BA, QBT114-10-1130 2BA, QBT120-10-1190 2BA
FAQ
Q:What to do when a safety light curtain malfunctions?
A:
Safety light curtains are important safety devices used to protect workers and equipment. However, even high-quality safety light curtains may experience malfunctions. This article will discuss common safety light curtain malfunctions and provide troubleshooting solutions to help you resolve the issues promptly.
1. Safety light curtain not functioning properly
If the safety light curtain is not functioning properly, first check if the power supply is working correctly. Ensure that the power cable is connected properly and check if the indicator lights on the light curtain are illuminated. If the indicator lights are on, it may indicate a power supply issue that requires either replacing the power supply or repairing the power cable.
Additionally, check the connection between the emitter and receiver of the light curtain to ensure it is secure. Sometimes, the connection may become loose or disconnected, resulting in the failure to transmit light signals. Reconnect the emitter and receiver, ensuring a secure connection.
2. False alarms from safety light curtain
If the safety light curtain is frequently producing false alarms, meaning it signals an alert even when no objects or personnel are entering, it may be experiencing interference. First, check the surrounding environment for any reflective objects or bright light sources. These objects or light sources can interfere with the proper operation of the light curtain.
Additionally, check if there are any obstacles blocking the transmission of light between the emitter and receiver of the light curtain. If there are objects or dust obstructing the transmission of light, remove them or reinstall the light curtain to ensure smooth light transmission.
3. Sensitivity issues with safety light curtain
If the sensitivity of the safety light curtain is either too high or too low, meaning it fails to produce an alert signal when obstacles are present, it may require adjusting the sensitivity settings. Refer to the user manual of the light curtain to learn how to adjust its sensitivity.
While adjusting the sensitivity, you can try gradually increasing or decreasing the sensitivity settings until you achieve the desired alert effect. If the issue persists, it may be necessary to check if the receiver of the safety light curtain is damaged or needs replacement.
For more complex malfunctions, it is recommended to seek assistance from professional technical support personnel for inspection and repair. They have extensive experience and expertise that can help you quickly resolve the issues with your safety light curtain.
In summary, when a safety light curtain malfunctions, first check if the power supply is working properly, and ensure that the connection between the light emitter and receiver is secure. If there are false alarms or sensitivity issues, settings can be adjusted or obstructions can be cleared. For complex malfunctions, it is recommended to seek professional technical support. Ensuring the proper functioning of the safety light curtain is crucial for protecting the safety of workers and equipment.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.