For Pilz PSENopt Series 250 mm, 267 mm, 225 mm, 300 mm Resolution 50 m Sensing Distance 500 mm to 1200 mm Protective Height Basic Type 2 Light Curtain with Body Protection Replacement
For Pilz PSENopt Series 250 mm, 267 mm, 225 mm, 300 mm Resolution 50 m Sensing Distance 500 mm to 1200 mm Protective Height Basic Type 2 Light Curtain with Body Protection Replacement
For Pilz PSENopt Series 250 mm, 267 mm, 225 mm, 300 mm Resolution 50 m Sensing Distance 500 mm to 1200 mm Protective Height Basic Type 2 Light Curtain with Body Protection Replacement
For Pilz PSENopt Series 250 mm, 267 mm, 225 mm, 300 mm Resolution 50 m Sensing Distance 500 mm to 1200 mm Protective Height Basic Type 2 Light Curtain with Body Protection Replacement
For Pilz PSENopt Series 250 mm, 267 mm, 225 mm, 300 mm Resolution 50 m Sensing Distance 500 mm to 1200 mm Protective Height Basic Type 2 Light Curtain with Body Protection Replacement
For Pilz PSENopt Series 250 mm, 267 mm, 225 mm, 300 mm Resolution 50 m Sensing Distance 500 mm to 1200 mm Protective Height Basic Type 2 Light Curtain with Body Protection Replacement
Model
PSENopt Series | PSEN op2B-2-050/1, PSEN op2B-3-080/1, PSEN op2B-4-090/1, PSEN op2B-4-120/1

Item specifics

Series:
PSENopt Series
Resolution:
250 mm, 267 mm, 225 mm, 300 mm
Scanning range:
0.5 - 50 m
Protective field height:
500 - 1200 mm
2 Safety outputs (OSSD):
2 PNP
Response time:
14 - 16 ms
Connection type:
M12
security level:
PLc2

Review

Description

For Pilz PSENopt Series 250 mm, 267 mm, 225 mm, 300 mm Resolution 50 m Sensing Distance 500 mm to 1200 mm Protective Height Basic Type 2 Light Curtain with Body Protection Replacement Parameter
Brand
From network
DADISICK
Models
PSEN op2B-2-050/1
QT04-200-600 2BH
PSEN op2B-3-080/1
QT06-200-1000 2BH
PSEN op2B-4-090/1
PSEN op2B-4-120/1
QT08-200-1400 2BH
Beam spacing
250 mm, 267 mm, 225 mm, 300 mm
200 mm
Protected altitude
500 mm, 800 mm, 900 mm, 1200 mm
600 mm, 1000 mm, 1400 mm
Scanning range
0.5 - 50 m
0.3 - 45 m
Response time
14 ms - 16 ms
≤15 ms
Output method
2 PNP
2 PNP
Reliability and durability
IP65
IP65
Connector
M12
M16
Housing cross-section
41.2 mm x 35 mm
51 mm x 35 mm
Safety Certificate
CE, cULus, TÜV
TÜV, UL, CE, RoHS, GB
We are able to reproduce the specific connection configuration of each brand with high level of accuracy.
Product model display instructions
The brands and specifications shown on this page are for product selection only. Our safety light curtain is a safety part made by DADISICK, not official brand Pilz's products. DAIDSICK offer replacement for official brand products. We are not the owner of the brands. If you need to buy official brand products, please contact the brand official representative.
Product recommendations
DADISICK QMT Series Machine Light Curtains
Model:
QT04-200-600 2BH
QT06-200-1000 2BH
QT06-200-1000 2BH
QT08-200-1400 2BH






FAQ
Q: Common misconception in selecting light curtain resolution?

A:
Quantifying the resolution of safety light curtains

In various types of safety light curtain products on the market, an important selection parameter is the resolution. The resolution is typically quantified in millimeters (mm), such as common values like 14mm, 20mm, 30mm, and so on. These quantified indicators represent the gap between the sensing functions of the safety light curtain sensors.

Is it an intuitive classification or a misconception?

According to different resolutions, safety light curtains are usually classified as finger, hand, and body protection types, which are used to indicate the most suitable application scenarios. However, this intuitive classification method is often misunderstood. Many designers believe that they can directly select the type of light curtain based on the body parts that can be injured by the hazard source. However, such a matching method often does not meet the requirements of standards

The correct selection method for safety light curtains.
According to the European standard EN ISO 13855, the minimum distance of safety light curtains from the hazard source should be calculated by taking parameters such as the resolution of the light curtain, installation method, and system's stopping response time into consideration. Different formulas apply for vertical, horizontal, and angled installations. Only by considering the resolution of the light curtain, positioning method, stopping response time, and distance from the hazard source in a comprehensive manner can we adhere to the standard and choose the correct method.
For example, if the light curtain selection for a certain device is based on a matching method and a hand protection type is chosen. However, if the positioning of the light curtain in relation to the hazard source is restricted or if the system's stopping response time is too long, it is necessary to consider increasing the resolution of the light curtain to meet the requirements of EN ISO 13855.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.
Safety Light Curtain Wiring Diagrams/Dimensional Drawings
safety light curtain Cable description
DADISICK Safety Light Curtain Cable Description
signal output selection (actual output of transistor working normally)
DADISICK Safety Light Curtain Signal Output Selection
NPN output wiring diagram
DADISICK Safety Light Curtain NPN Output Wiring Diagram
PNP output wiring diagram
DADISICK Safety Light Curtain PNP Output Wiring Diagram
safety light curtain Dimension
DADISICK Safety Light Curtain Dimension
Safety-light-curtain QT series-data sheet
Safety-light-curtain QT series user manual