For Safetytec Red4 Series 14 mm Resolution 5 m Sensing Distance 125 mm to 1285 mm Protective Height Safety Lightguard Replacement
- Model
- Red4 Series | RED4/14-PH125/L, RED4/14-PH270/L, RED4/14-PH415/L, RED4/14-PH560/L, RED4/14-PH705/L, RED4/14-PH850/L, RED4/14-PH995/L, RED4/14-PH1140/L, RED4/14-PH1285/L
Item specifics
- Series:
- Red4 Series
- Resolution:
- 14 mm
- Scanning range:
- 0 - 5 m
- Protective field height:
- 125 mm - 1285 mm
- 2 Safety outputs (OSSD):
- 2 NPN
- Response time:
- 10 - 60 ms
- Connection type:
- M12
- security level:
- PLe4
Review
Description
For Safetytec Red4 Series 14 mm Resolution 5 m Sensing Distance 125 mm to 1285 mm Protective Height Safety Lightguard Replacement Parameter
Brand | From network | DADISICK |
|
Models
|
RED4/14-PH125/L | QM14-10-130 2AB |
|
RED4/14-PH270/L |
QM28-10-270 2AB | ||
RED4/14-PH415/L | QM42-10-410 2AB |
||
RED4/14-PH560/L | QM56-10-550 2AB | ||
RED4/14-PH705/L | QM72-10-710 2AB | ||
RED4/14-PH850/L | QM86-10-850 2AB | ||
RED4/14-PH995/L | QM102-10-1010 2AB | ||
RED4/14-PH1140/L | QM114-10-1130 2AB | ||
RED4/14-PH1285/L | QM130-10-1290 2AB | ||
Beam spacing | 14 mm | 10 mm | |
Protected altitude | 125 mm, 270 mm, 415 mm, 560 mm, 705 mm, 850 mm, 995mm, 1140 mm, 2396 mm | 130 mm, 270 mm, 410 mm, 550 mm, 710 mm, 850 mm, 1010mm, 1130 mm, 1290 mm | |
Scanning range | 0 - 5 m | 0.3 - 6 m | |
Response time | 10 - 60 ms | ≤15 ms | |
Output method | 2 NPN | 2 NPN | |
Reliability and durability | IP65 | IP65 | |
Connector | M12 | M12 | |
Housing cross-section | 41 mm x 46 mm | 36 mm x 36 mm | |
Safety Certificate | CE, UKCA | TÜV, UL, CE, RoHS, GB | |
We are able to reproduce the specific connection configuration of each brand with high level of accuracy. |
Product model display instructions
The brands and specifications shown on this page are for product selection only. Our safety light curtain is a safety part made by DADISICK, not official brand Safetytec's products. DAIDSICK offer replacement for official brand products. We are not the owner of the brands. If you need to buy official brand products, please contact the brand official representative.
Product recommendations
Model:
QM14-10-130 2AB, QM28-10-270 2AB, QM42-10-410 2AB
QM56-10-550 2AB, QM72-10-710 2AB, QM86-10-850 2AB
QM102-10-1010 2AB, QM114-10-1130 2AB, QM130-10-1290 2AB
FAQ
Q: What is an infrared high-precision measurement and detection light curtain?
A:
With the rapid development of industry, the operation and control technology of machines are becoming more advanced, and automated equipment has become an essential tool in modern factories. However, if safety precautions are not properly implemented, there could be potential safety hazards in hazardous work areas such as punching machines, hydraulic presses, oil presses, intelligent warehousing, and industrial robots. The application of infrared light grid sensors in the field of safety protection is known as safety light curtains/safety light screens/optical protective devices, etc.
As the precision requirements for workpieces increase and labor costs become more expensive, along with the widespread use of automated equipment, many industries choose to use automated or semi-automated solutions to overcome tedious and repetitive manual measurements. These solutions are commonly used for measuring the shape, size, volume contour of objects, hole detection, classification detection, positioning detection, edge detection, height limitation detection, vehicle separation, and other aspects.
DADISICK's measurement light curtains are derived from safety light curtains and have higher accuracy and technical requirements. Their principle is based on detecting changes in the shape of objects passing through the infrared light curtain by sensing whether the infrared light is obstructed and the number of obstructing blocks.
Safety light curtains are commonly used for safety protection and detection positioning. Typically, safety light curtains are used as switch signals, with normally closed mode used for personal safety protection and normally open mode used for detecting the position of workpiece products
DADISICK's QL measurement light curtains usually communicate with safety light curtains using RS485/RS232/analog current/analog voltage. Of course, we also support network port output. The purpose is to transmit the signals detected by the measurement light curtains through communication to the PLC or controller to obtain the required data.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.