Model
SLCS60/35 Series | SLCS60-0300-R/35, SLCS60-0300-T/35, SLCS60-0600-R/35, SLCS60-0600-T/35, SLCS60-0900-R/35, SLCS60-0900-T/35, SLCS60-1200-R/35, SLCS60-1200-T/35, SLCS60-1500-R/35, SLCS60-1500-T/35, SLCS60-1800-R/35, SLCS60-1800-T/35, SLCS60-2100-R/35, SLCS60-2100-T/35, SLCS60-2400-R/35, SLCS60-2400-T/35

Item specifics

Series:
SLCS60/35 Series
Resolution:
60 mm
Scanning range:
5 - 20 m
Protective field height:
300 - 2400 mm
2 Safety outputs (OSSD):
2 PNP
Response time:
9 - 23 ms
Connection type:
M12
security level:
PLe4

Review

Description

For PEPPERL+FUCHS SLCS60/35 Series 60 mm Resolution 20 m Sensing Distance 300 mm to 2400 mm Protective Height Base Light Curtain Replacement Parameter
Brand
Receiver
Transmitter
DADISICK
Models
SLCS60-0300-R/35
SLCS60-0300-T/35
QT08-40-280 2BE
SLCS60-0600-R/35
SLCS60-0600-T/35
QT16-40-600 2BE
SLCS60-0900-R/35
SLCS60-0900-T/35
QT24-40-920 2BE
SLCS60-1200-R/35
SLCS60-1200-T/35
QT30-40-1160 2BE
SLCS60-1500-R/35
SLCS60-1500-T/35
QT38-40-1480 2BE
SLCS60-1800-R/35
SLCS60-1800-T/35
QT46-40-1800 2BE
SLCS60-2100-R/35
SLCS60-2100-T/35
QT54-40-2120 2BE
SLCS60-2400-R/35
SLCS60-2400-T/35
QT60-40-2360 2BE
Beam spacing
60 mm
40 mm
Protected altitude
300 mm, 600 mm, 900 mm, 1200 mm, 1500 mm, 1800 mm, 2100 mm, 2400 mm
280 mm, 600 mm, 920 mm, 1160 mm, 1480 mm, 1800 mm, 2120 mm, 2360 mm
Scanning range
5 - 20 m
0.3 - 20 m
Response time
9 ms - 23 ms
≤15 ms
Output method
2 PNP
2 PNP
Reliability and durability
IP67
IP65
Connector
M12
M16
Housing cross-section
20 mm x 29.5 mm
51 mm x 35 mm
Safety Certificate
  TÜV, UL, EC, UKCA
TÜV, UL, CE, RoHS, GB
We are able to reproduce the specific connection configuration of each brand with high level of accuracy.
Product model display instructions
The brands and specifications shown on this page are for product selection only. Our safety light curtain is a safety part made by DADISICK, not official brand PEPPERL+FUCHS's products. DAIDSICK offer replacement for official brand products. We are not the owner of the brands. If you need to buy official brand products, please contact the brand official representative.
Product recommendations
DADISICK QT Series Machine Light Curtains
Model:
QT08-40-280 2BE, QT16-40-600 2BE, QT24-40-920 2BE
QT30-40-1160 2BE, QT38-40-1480 2BE, QT46-40-1800 2BE
QT54-40-2120 2BE, QT60-40-2360 2BE





FAQ
Q:The through-beam type safety light curtain consists of which parts?
A:
In industrial production, safety has always been a pressing issue. Many machinery and equipment pose high risks and pose a significant threat to the personal safety of operators. Various accidents, big and small, have been occurring frequently in the mechanical industry. However, with the emergence of through-beam safety light curtains (also known as safety light grids or photoelectric protective devices), this problem has been effectively addressed.

DADISCHER Safety Light Curtain is a protective device used to ensure equipment safety in production, providing maximum protection for the personal safety of operators and enabling safe industrial production.
DADISCHER Safety Light Curtain has a wide range of applications, and its main components include: emitter, receiver, signal cable, controller, and mounting brackets.

Emitter: primarily used to emit infrared beams.

Receiver: primarily used to receive the infrared beams emitted by the emitter.

Signal cable: used to transmit the control signals returned by the safety light curtain.

Controller: responsible for supplying power to the emitter and receiver, as well as processing the light transmission and obstruction signals generated by the receiver's infrared beams to generate control signals.

Mounting brackets: brackets used during the installation process of the safety light curtain. They include L1 type brackets, L2 type brackets, J-type reinforced brackets, and N-type aluminum cantilever brackets (T-type iron cantilever).
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.
Safety Light Curtain Wiring Diagrams/Dimensional Drawings
safety light curtain Cable description
DADISICK Safety Light Curtain Cable Description
signal output selection (actual output of transistor working normally)
DADISICK Safety Light Curtain Signal Output Selection
NPN output wiring diagram
DADISICK Safety Light Curtain NPN Output Wiring Diagram
PNP output wiring diagram
DADISICK Safety Light Curtain PNP Output Wiring Diagram
safety light curtain Dimension
DADISICK Safety Light Curtain Dimension