For OMRON F3SG-RE Series Safety Light Curtain Replacement 2PNP Output 20 mm Resolution | 20 m Operating Range | 190 mm to 1390 mm Protective Height
For OMRON F3SG-RE Series Safety Light Curtain Replacement 2PNP Output 20 mm Resolution | 20 m Operating Range | 190 mm to 1390 mm Protective Height
For OMRON F3SG-RE Series Safety Light Curtain Replacement 2PNP Output 20 mm Resolution | 20 m Operating Range | 190 mm to 1390 mm Protective Height
For OMRON F3SG-RE Series Safety Light Curtain Replacement 2PNP Output 20 mm Resolution | 20 m Operating Range | 190 mm to 1390 mm Protective Height
For OMRON F3SG-RE Series Safety Light Curtain Replacement 2PNP Output 20 mm Resolution | 20 m Operating Range | 190 mm to 1390 mm Protective Height
For OMRON F3SG-RE Series Safety Light Curtain Replacement 2PNP Output 20 mm Resolution | 20 m Operating Range | 190 mm to 1390 mm Protective Height
Model
F3SG-RE Series | F3SG-4RE0190P30, F3SG-4RE0270P30, F3SG-4RE0350P30, F3SG-4RE0430P30, F3SG-4RE0510P30, F3SG-4RE0590P30, F3SG-4RE0670P30, F3SG-4RE0750P30, F3SG-4RE0830P30, F3SG-4RE0910P30, F3SG-4RE0990P30, F3SG-4RE1070P30, F3SG-4RE1150P30, F3SG-4RE1230P30, F3SG-4RE1310P30, F3SG-4RE1390P30

Item specifics

Series:
F3SG-RE Series
Resolution:
20 mm
Scanning range:
0.3 m - 20 m
Protective field height:
190 mm - 1390 mm
2 Safety outputs (OSSD):
2 PNP
Response time:
5 ms - 9 ms
Connection type:
M12
Security level:
PLe4

Review

Description

For OMRON F3SG-RE Series Safety Light Curtain Replacement  Parameter
Brand
From network
DADISICK
Models
F3SG-4RE0190P30
QT10-20-180-2BE
F3SG-4RE0270P30
QT14-20-260-2BE
F3SG-4RE0350P30
QT18-20-340-2BE
F3SG-4RE0430P30
QT22-20-420-2BE
F3SG-4RE0510P30
QT26-20-500-2BE
F3SG-4RE0590P30
QT30-20-580-2BE
F3SG-4RE0670P30
QT34-20-660-2BE
F3SG-4RE0750P30
QT38-20-740-2BE
F3SG-4RE0830P30
QT42-20-820-2BE
F3SG-4RE0910P30
QT46-20-900-2BE
F3SG-4RE0990P30
QT50-20-980-2BE
F3SG-4RE1070P30
QT54-20-1060-2BE
F3SG-4RE1150P30
QT58-20-1140-2BE
F3SG-4RE1230P30
QT62-20-1220-2BE
F3SG-4RE1310P30
QT66-20-1300-2BE
F3SG-4RE1390P30
QT70-20-1380-2BE
Beam spacing
20 mm
20 mm
Protected altitude
190 mm, 270 mm, 350 mm, 430 mm, 
510 mm, 590 mm, 670 mm, 750 mm, 
830 mm, 910 mm, 990 mm, 1070 mm, 
1150 mm, 1230 mm, 1310 mm, 1390 mm
180 mm, 260 mm, 340 mm, 420 mm, 
500 mm, 580 mm, 660 mm, 740 mm, 
820 mm, 900 mm, 980 mm, 1060 mm, 
1140 mm, 1220 mm, 1300 mm, 1380 mm
Scanning range
0.3 m - 20 m
0.3 m - 20 m
Response time
5 ms - 9 ms
≤15 ms
Output method
2 PNP
2 PNP
Reliability and durability
IP65 / IP67
IP65
Connector
M12
M16
Housing cross-section
50.35 mm × 35 mm
35 mm × 51 mm
Safety Certificate
CE, TÜV, UL
TÜV, UL, CE, RoHS, GB
We are able to reproduce the specific connection configuration of each brand with high level of accuracy.
Product model display instructions
The brands and specifications shown on this page are for product selection only. Our safety light curtain is a safety part made by DADISICK, not official brand OMRON's products. DAIDSICK offer replacement for official brand products. We are not the owner of the brands. If you need to buy official brand products, please contact the brand official representative.
Product recommendations
DADISICK Safety Light Curtains
Model:
QT10-20-180-2BE, QT14-20-260-2BE, QT18-20-340-2BE, QT22-20-420-2BE, QT26-20-500-2BE, QT30-20-580-2BE, QT34-20-660-2BE, QT38-20-740-2BE, QT42-20-820-2BE, QT46-20-900-2BE, QT50-20-980-2BE, QT54-20-1060-2BE, QT58-20-1140-2BE, QT62-20-1220-2BE, QT66-20-1300-2BE, QT70-20-1380-2BE

FAQ
What are the requirements for the working environment of safety light curtains?
The requirements for the working environment of safety light curtains include:

1.Temperature: The environmental temperature should be within the range of -10℃ to 55℃. Excessive temperatures, either too high or too low, may affect the normal operation of the safety light curtain.
2.Humidity: The air relative humidity should not exceed 95%. High humidity may cause condensation on the optical components, affecting their performance.
3.Media: The air should be free of media that can trigger explosions or corrode metals and damage insulation.
4.Vibration: The vibration amplitude and corresponding frequency should conform to national standards. Excessive vibration may damage internal components of the safety light curtain.
5.Lighting: Direct sunlight or other strong light sources should be avoided, as they may interfere with the detection accuracy of the safety light curtain.
6.Dust and dirt: Environments with excessive dust or dirt may accumulate on the optical surfaces of the safety light curtain, reducing its transmission efficiency. Regular cleaning and maintenance are required.
7.Reflective surfaces: Surfaces that can reflect light should be avoided in the vicinity of the safety light curtain, as reflected light may interfere with its operation.
8.Interference sources: The installation location should be free of interference sources that can affect the signal transmission of the safety light curtain, such as electromagnetic fields.
9.Space: The installation space should allow for the correct alignment and adjustment of the transmitter and receiver units of the safety light curtain.

It is important to note that the specific requirements for the working environment of safety light curtains may vary depending on the model, manufacturer, and intended application. It is recommended to consult the manufacturer's specifications and installation instructions for detailed information.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.
Safety Light Curtain Wiring Diagrams/Dimensional Drawings
safety light curtain Cable description
DADISICK Safety Light Curtain Cable Description
signal output selection (actual output of transistor working normally)
DADISICK Light Curtain Signal Output Selection
NPN output wiring diagram
DADISICK Light Curtain NPN Output Wiring Diagram
PNP output wiring diagram
DADISICK Light Curtain PNP Output Wiring Diagram
safety light curtain Dimension
DADISICK Safety Light Curtain Dimension
Safety-light-curtain QT Series Data Sheet
Safety-light-curtain QT Series User Manual