For IFM OY Series Safety Light Curtain Type 2 for Factory Automation Replacement 30 mm Resolution | 4 m Operating Range | 1810 mm Protective Height
For IFM OY Series Safety Light Curtain Type 2 for Factory Automation Replacement 30 mm Resolution | 4 m Operating Range | 1810 mm Protective Height
For IFM OY Series Safety Light Curtain Type 2 for Factory Automation Replacement 30 mm Resolution | 4 m Operating Range | 1810 mm Protective Height
For IFM OY Series Safety Light Curtain Type 2 for Factory Automation Replacement 30 mm Resolution | 4 m Operating Range | 1810 mm Protective Height
For IFM OY Series Safety Light Curtain Type 2 for Factory Automation Replacement 30 mm Resolution | 4 m Operating Range | 1810 mm Protective Height
For IFM OY Series Safety Light Curtain Type 2 for Factory Automation Replacement 30 mm Resolution | 4 m Operating Range | 1810 mm Protective Height
Model
OY Series | OY300S

Item specifics

Series:
OY Series
Resolution:
30 mm
Scanning range:
0...4 m
Protective field height:
1810 mm
2 Safety outputs (OSSD):
2 PNP
Response time:
19.5 ms
Connection type:
M12
Security level:
PLc2

Review

Description

For IFM OY Series Safety Light Curtain Type 2 for Factory Automation Replacement Parameter
Brand
From network
DADISICK
Models
OY300S
QCE62-30-1830 2BB
Beam spacing
30 mm
30 mm
Protected altitude
1810 mm
1830 mm
Scanning range
0...4 m
0.3 m - 6 m
Response time
19.5 ms
≤ 15 ms
Output method
2 PNP
2 PNP
Reliability and durability
IP65 / IP67
IP65
Connector
M12
M12
Housing cross-section
28 mm × 30 mm
30 mm × 30 mm
Safety Certificate
CE, UKCA, UL
TÜV, UL, CE, RoHS, GB
We are able to reproduce the specific connection configuration of each brand with high level of accuracy.
Product model display instructions
The brands and specifications shown on this page are for product selection only. Our safety light curtain is a safety part made by DADISICK, not official brand IFM's products. DAIDSICK offer replacement for official brand products. We are not the owner of the brands. If you need to buy official brand products, please contact the brand official representative.
Product recommendations
FAQ
After installing the new light curtain, what tests should I conduct?
We recommend conducting functional tests and safety validations to ensure the new light curtain operates properly. Test items include detection range, response time, and alarm functions, among others.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.
Safety Light Curtain Wiring Diagrams/Dimensional Drawings
safety light curtain Cable description
DADISICK Safety Light Curtain Cable Description
signal output selection (actual output of transistor working normally)
DADISICK Light Curtain Signal Output Selection
NPN output wiring diagram
DADISICK Light Curtain NPN Output Wiring Diagram
PNP output wiring diagram
DADISICK Light Curtain PNP Output Wiring Diagram
safety light curtain Dimension
DADISICK Safety Light Curtain Dimension
Safety-light-curtain QCE Series Data Sheet
Safety-light-curtain QCE Series User Manual