For IFM OY Series Safety Light Curtain Type 4 for Factory Automation Replacement 90 mm Resolution | 10 m Operating Range | 1510 mm Protective Height
For IFM OY Series Safety Light Curtain Type 4 for Factory Automation Replacement 90 mm Resolution | 10 m Operating Range | 1510 mm Protective Height
For IFM OY Series Safety Light Curtain Type 4 for Factory Automation Replacement 90 mm Resolution | 10 m Operating Range | 1510 mm Protective Height
For IFM OY Series Safety Light Curtain Type 4 for Factory Automation Replacement 90 mm Resolution | 10 m Operating Range | 1510 mm Protective Height
For IFM OY Series Safety Light Curtain Type 4 for Factory Automation Replacement 90 mm Resolution | 10 m Operating Range | 1510 mm Protective Height
For IFM OY Series Safety Light Curtain Type 4 for Factory Automation Replacement 90 mm Resolution | 10 m Operating Range | 1510 mm Protective Height
Model
OY Series | OY210S

Item specifics

Series:
OY Series
Resolution:
90 mm
Scanning range:
0...10 m
Protective field height:
1510 mm
2 Safety outputs (OSSD):
2 PNP
Response time:
4.5 ms
Connection type:
M12
Security level:
PLe4

Review

Description

For IFM OY Series Safety Light Curtain Type 4 for Factory Automation Replacement Parameter
Brand
From network
DADISICK
Models
OY210S
QM20-80-1520-2BB
Beam spacing
90 mm
80 mm
Protected altitude
1510 mm
1520 mm
Scanning range
0...10 m
0.3 m - 6 m
Response time
4.5 ms
≤ 15 ms
Output method
2 PNP
2 PNP
Reliability and durability
IP65 / IP67
IP65
Connector
M12
M12
Housing cross-section
28 mm × 30 mm
36 mm × 36 mm
Safety Certificate
CE, UKCA, UL
TÜV, UL, CE, RoHS, GB
We are able to reproduce the specific connection configuration of each brand with high level of accuracy.
Product model display instructions
The brands and specifications shown on this page are for product selection only. Our safety light curtain is a safety part made by DADISICK, not official brand IFM's products. DAIDSICK offer replacement for official brand products. We are not the owner of the brands. If you need to buy official brand products, please contact the brand official representative.
Product recommendations
FAQ
If the safety light curtain's grid does not respond or has a delayed response, follow these steps:
1.Check the power supply connection and the wiring between the light curtain and the controller.
2.It may be necessary to recalibrate the light curtain.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.
Safety Light Curtain Wiring Diagrams/Dimensional Drawings
safety light curtain Cable description
DADISICK Safety Light Curtain Cable Description
signal output selection (actual output of transistor working normally)
DADISICK Light Curtain Signal Output Selection
NPN output wiring diagram
DADISICK Light Curtain NPN Output Wiring Diagram
PNP output wiring diagram
DADISICK Light Curtain PNP Output Wiring Diagram
safety light curtain Dimension
DADISICK Safety Light Curtain Dimension
Safety-light-curtain QM Series Data Sheet
Safety-light-curtain QM Series User Manual

recommend