For Autonics SFL Series Safety Light Curtain Standard Type Replacement 15 mm Resolution Hand Protection | 15 m Operating Range | 183 mm to 1023 mm Protective Height
For Autonics SFL Series Safety Light Curtain Standard Type Replacement 15 mm Resolution Hand Protection | 15 m Operating Range | 183 mm to 1023 mm Protective Height
For Autonics SFL Series Safety Light Curtain Standard Type Replacement 15 mm Resolution Hand Protection | 15 m Operating Range | 183 mm to 1023 mm Protective Height
For Autonics SFL Series Safety Light Curtain Standard Type Replacement 15 mm Resolution Hand Protection | 15 m Operating Range | 183 mm to 1023 mm Protective Height
For Autonics SFL Series Safety Light Curtain Standard Type Replacement 15 mm Resolution Hand Protection | 15 m Operating Range | 183 mm to 1023 mm Protective Height
For Autonics SFL Series Safety Light Curtain Standard Type Replacement 15 mm Resolution Hand Protection | 15 m Operating Range | 183 mm to 1023 mm Protective Height
Model
SFL Series | SFL20-12, SFL20-16, SFL20-20, SFL20-24, SFL20-28, SFL20-32, SFL20-36, SFL20-40, SFL20-44, SFL20-48, SFL20-52, SFL20-56, SFL20-60, SFL20-64, SFL20-68

Item specifics

Series:
SFL Series
Resolution:
15 mm
Scanning range:
0.2 m - 15 m
Protective field height:
183 mm - 1023 mm
2 Safety outputs (OSSD):
2 PNP
Response time:
19.9 ms
Connection type:
M12
Security level:
PLe4

Review

Description

For Autonics SFL Series Safety Light Curtain Standard Type Replacement Parameter
Brand
From network
DADISICK
Models
SFL20-12
SFL20-16
SFL20-20
SFL20-24
SFL20-28
SFL20-32
SFL20-36
SFL20-40
SFL20-44
SFL20-48
SFL20-52
SFL20-56
SFL20-60
SFL20-64
SFL20-68
Beam spacing
15 mm
10 mm
Protected altitude
183 mm, 243 mm, 303 mm, 363 mm, 
423 mm, 483 mm, 543 mm, 603 mm, 
663 mm, 723 mm, 783 mm, 843 mm, 
903 mm, 963 mm, 1023 mm
190 mm, 250 mm, 310 mm, 370 mm, 
430 mm, 490 mm, 550 mm, 610 mm, 
670 mm, 730 mm, 790 mm, 850 mm, 
910 mm, 970 mm, 1030 mm
Scanning range
0.2 m - 15 m
0.3 m - 15 m
Response time
19.9 ms
≤15 ms
Output method
2 PNP
2 PNP
Reliability and durability
IP65 / IP67 / IP67G / IP69K
IP65
Connector
M12
M12
Housing cross-section
29 mm × 35 mm
36 mm × 36 mm
Safety Certificate
TÜV, UL, CE, UKCA, RoHS, S-Mark, KCs
TÜV, UL, CE, RoHS, GB
We are able to reproduce the specific connection configuration of each brand with high level of accuracy.
Product model display instructions
The brands and specifications shown on this page are for product selection only. Our safety light curtain is a safety part made by DADISICK, not official brand Autonics's products. DAIDSICK offer replacement for official brand products. We are not the owner of the brands. If you need to buy official brand products, please contact the brand official representative.
Product recommendations
DADISICK Safety Light Curtains
Model:
QM20-10-190-2BD, QM26-10-250-2BD, QM32-10-310-2BD, QM38-10-370-2BD, QM44-10-430-2BD, QM50-10-490-2BD, QM56-10-550-2BD, QM62-10-610-2BD, QM68-10-670-2BD, QM74-10-730-2BD, QM80-10-790-2BD, QM86-10-850-2BD, QM92-10-910-2BD, QM98-10-970-2BD, QM104-10-1030-2BD

FAQ
What are the requirements for the working environment of safety light curtains?
The requirements for the working environment of safety light curtains include:

1.Temperature: The environmental temperature should be within the range of -10℃ to 55℃. Excessive temperatures, either too high or too low, may affect the normal operation of the safety light curtain.
2.Humidity: The air relative humidity should not exceed 95%. High humidity may cause condensation on the optical components, affecting their performance.
3.Media: The air should be free of media that can trigger explosions or corrode metals and damage insulation.
4.Vibration: The vibration amplitude and corresponding frequency should conform to national standards. Excessive vibration may damage internal components of the safety light curtain.
5.Lighting: Direct sunlight or other strong light sources should be avoided, as they may interfere with the detection accuracy of the safety light curtain.
6.Dust and dirt: Environments with excessive dust or dirt may accumulate on the optical surfaces of the safety light curtain, reducing its transmission efficiency. Regular cleaning and maintenance are required.
7.Reflective surfaces: Surfaces that can reflect light should be avoided in the vicinity of the safety light curtain, as reflected light may interfere with its operation.
8.Interference sources: The installation location should be free of interference sources that can affect the signal transmission of the safety light curtain, such as electromagnetic fields.
9.Space: The installation space should allow for the correct alignment and adjustment of the transmitter and receiver units of the safety light curtain.

It is important to note that the specific requirements for the working environment of safety light curtains may vary depending on the model, manufacturer, and intended application. It is recommended to consult the manufacturer's specifications and installation instructions for detailed information.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.
Safety Light Curtain Wiring Diagrams/Dimensional Drawings
safety light curtain Cable description
DADISICK Safety Light Curtain Cable Description
signal output selection (actual output of transistor working normally)
DADISICK Light Curtain Signal Output Selection
NPN output wiring diagram
DADISICK Light Curtain NPN Output Wiring Diagram
PNP output wiring diagram
DADISICK Light Curtain PNP Output Wiring Diagram
safety light curtain Dimension
DADISICK Safety Light Curtain Dimension
Safety-light-curtain QM Series Data Sheet
Safety-light-curtain QM Series User Manual

recommend