Model
SL-V Series | SL-V36L, SL-V40L, SL-V44L, SL-V48L, SL-V52L, SL-V56L, SL-V60L

Item specifics

Series:
SL-V Series
Resolution:
40 mm
Scanning range:
0.1 m - 7 m
Protective field height:
1485 mm - 2445 mm
2 Safety outputs (OSSD):
2 PNP
Response time:
10.9 ms - 14.2 ms
Connection type:
M12
Security level:
PLe4

Review

Description

For KEYENCE SL-V Series Safety Light Curtain Replacement Parameter
Brand
From network
DADISICK
Models
SL-V36L
SL-V40L
SL-V44L
SL-V48L
SL-V52L
SL-V56L
SL-V60L
Beam spacing
40 mm
40 mm
Protected altitude
1485 mm, 1645 mm, 1805 mm, 1965 mm, 
2125 mm, 2285 mm, 2445 mm
1480 mm, 1640 mm, 1800 mm, 1960 mm, 
2120 mm, 2280 mm, 2440 mm
Scanning range
0.1 m - 7 m
0.3 m - 10 m
Response time
10.9 ms - 14.2 ms
≤15 ms
Output method
2 PNP
2 PNP
Reliability and durability
IP65
IP65
Connector
M12
M16
Housing cross-section
33.2 mm × 26 mm
35 mm × 51 mm
Safety Certificate
CE, UL
TÜV, UL, CE, RoHS, GB
We are able to reproduce the specific connection configuration of each brand with high level of accuracy.
Product model display instructions
The brands and specifications shown on this page are for product selection only. Our safety light curtain is a safety part made by DADISICK, not official brand KEYENCE's products. DAIDSICK offer replacement for official brand products. We are not the owner of the brands. If you need to buy official brand products, please contact the brand official representative.
Product recommendations
DADISICK Safety Light Curtains
Model:
QT38-40-1480-2BC, QT42-40-1640-2BC, QT46-40-1800-2BC, QT50-40-1960-2BC, QT54-40-2120-2BC, QT58-40-2280-2BC, QT62-40-2440-2BC

FAQ
What is the blanking function of a safety light curtain?
The blanking function of a safety light curtain is a feature that temporarily disables or ignores the detection capability of certain areas of the light curtain under specific conditions. This function is commonly used in production lines or machinery that require frequent intervention or movement of objects, to avoid frequent triggering of the light curtain, which could cause machine downtime or work interruptions.

Specifically, the blanking function can be applied in the following ways:

1.Selective Protection of Work Areas: It allows for the movement of materials or operations within specific areas without triggering the light curtain. For example, on a production line where materials frequently pass through the light curtain on a conveyor belt, the blanking function can temporarily disable detection in that area to prevent unnecessary shutdowns.
2.Handling Partial Obstruction of the Curtain: During production, if certain objects partially obstruct the safety light curtain, the blanking function can cause the system to ignore these specific obstructed parts, ensuring continuous operation of the production line.
3.Simplifying Equipment Debugging and Maintenance: During equipment debugging and maintenance, using the blanking function allows technicians to work without completely disabling the safety system, thereby improving efficiency and safety.

There are various methods to implement the blanking function, which can be achieved through hardware or software. For example, by setting parameters on the light curtain controller or using models of light curtains with built-in blanking functions. This function needs to be carefully configured and debugged to ensure it does not compromise overall safety, providing convenience while still safeguarding operators.

Overall, the blanking function enhances the adaptability and flexibility of safety light curtains in complex operational environments, allowing equipment to run more efficiently while maintaining safety.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.
Safety Light Curtain Wiring Diagrams/Dimensional Drawings
safety light curtain Cable description
DADISICK Safety Light Curtain Cable Description
signal output selection (actual output of transistor working normally)
DADISICK Light Curtain Signal Output Selection
NPN output wiring diagram
DADISICK Light Curtain NPN Output Wiring Diagram
PNP output wiring diagram
DADISICK Light Curtain PNP Output Wiring Diagram
safety light curtain Dimension
DADISICK Safety Light Curtain Dimension
Safety-light-curtain QT Series Data Sheet
Safety-light-curtain QT Series User Manual

recommend