Safety Relay Replacement Template
Safety Relay Replacement Template
Safety Relay Replacement Template
Safety Relay Replacement Template
Safety Relay Replacement Template
Safety Relay Replacement Template
Model
Safety Relay Replacement Template

Item specifics

Supply voltage
24 V, AC/DC
Power consumption
AC: 4 VA, DC: 2 W
Number of outputs
1
Relay contact material
AgCuNi
Operating temperature
-10 - 55 °C
Housing material
ABS UL 94 V0
Connection terminal
Screw terminal

Review

Description

PNOZ X Safety Relay Replacement Parameter
Brand
From network
DADISICK
Models
PNOZ X1 24VAC/DC 3n/o 1n/c
Ter-A
Supply voltage
24 V, AC/DC
24 V, DC
Power consumption
AC: 4 VA, DC: 2 W
1.5W
Relay contact material
AgCuNi
AgSn02 + 0.2mAu
Operating temperature
-10 - 55 °C
-25℃ - 85℃
Housing material
ABS UL 94 V0
Flame retardant PA66
Output
3 N/O, 1 N/C
3NO+1NC
Connection terminal
Screw terminal
Screw terminal
Relay contact capacity
AC-1
240 V, 6 A
6A/250VAC/1500VA
AC-15
230 V,  5 A
4A/240VAC
DC-1
24 V, 6 A
6A/24VDC/150W
DC-13
24 V
4A/24VDC
Product model display instructions
The product models displayed on this page are only used to describe and compare the characteristics, specifications, and performance of different products. These models do not represent recommendations or associations for any specific brand or company. When users choose products, please understand and compare the detailed information of each brand's products on your own.
Safety Relay Recommendations
DADISICK Safety Relay
Ter-A is a versatile safety relay that acts as the vital link between industrial safety equipment and control systems, ensuring seamless integration and optimal safety performance. Beside afety light curtain signals, it is suitable for industrial sites with high safety requirements. It monitors various signals, including emergency stop signals, safety door switch signals, safety grating signals, two-hand button signals, etc. Its main function is to protect machine operators and mechanical equipment exposed to different degrees of danger.

Ter-A series safety edges
Models:
Ter-A

Safety Relay FAQ
Q: If a safety relay disconnects the circuit during use, is it a device failure or a dangerous factor detected?
A: Circuit breakage can be caused by many factors. First, check whether there are any dangerous factors, such as potential circuit accidents. If it is confirmed that there are no hidden dangers, the safety relay may be faulty. At this point, you can try restarting the relay. If the problem persists, you need to troubleshoot or replace the relay.
Q: What should I do if the safety relay output contact fuse?
A: The output contact fuse of safety relay, it is usually caused by a short circuit fault or overcurrent. At this time, the new fuse should be replaced and the circuit should be checked for short circuit or overcurrent problems to avoid similar faults from happening again.
Q: What is the difference between automatic reset and manual reset?
A: Automatic reset means there is no reset switch in the feedback circuit and the device starts automatically when the input is turned on. Manual reset means there is a reset switch in the feedback circuit, and when the input is open, the device will not start unless the reset switch is pressed. Manual reset is basically safer and it must be performed after all hazards have been cleared. Therefore, manual reset is used for machines and emergency stop circuits that personnel can enter, and automatic reset is used for machines that personnel cannot enter.
Q: What is the reason why the safety relay contacts cannot separate?
A: Failure separation of the safety relay contacts can be caused by mechanical bonding, welding, or cold welding. In addition, low contact capacity, heavy load, or changes in load characteristics can also cause failure to connect or disconnect the circuit. At this time, check the contact status and replace or adjust if necessary.
Q: How to adjust the operating parameters of the safety relay?
A: When adjusting the operating parameters of a safety relay, its technical parameters, such as contact thickness, open gap, overtravel and terminal pressure, should be measured first to ensure that all parameters meet the requirements of relevant regulations and working documents. Then, adjust the set value of the action parameter according to actual requirements and fix it with stop paint.
Q: What precautions should be taken when using safety relays in combination with other components?
A: When using safety relays in combination with other components, ensure compatibility and coordination between the components. At the same time, relevant safety regulations and operating procedures should be followed to ensure the safety and stability of the entire circuit system.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.
Safety Relay Dimensions  (Unit: mm)
Safety Relay Ter-A Series Dimensions
Safety Relay Ter-A Output Wiring Diagram
Safety Relay Ter-A Series Dimensions
Safety Relay Ter-A.STEP

Safety Relay Ter-A Product Manual