For Euchner TZ Series with Door and Lock Monitoring 2 Contacts Mechanical Lock Solenoid Release Safety Switch Replacement
- Model
- TZ Series | TZ1LE024M, TZ1LE024M-089470, TZ1LE024M-C1623, TZ1LE024M-C1684, TZ1LE024M-C1815, TZ1LE024M-C1816, TZ1LE024M-C2087, TZ1LE024M-R, TZ1LE024PGOR8C, TZ1LE024SR11, TZ1LE024SR11-093860, TZ1LE024SR11-C1684, TZ1LE024SR11-C1816, TZ1LE024SR6, TZ1LE024SR6-C1638, TZ1LE024SR6-C1677, TZ1LE110M, TZ1LE110M-R, TZ1LE110PGOR8C, TZ1LE110SR6, TZ1LE220M, TZ1LE220M-C1684, TZ1LE220SR6, TZ1RE024M, TZ1RE024M-089471, TZ1RE024M-C1623, TZ1RE024M-C1684, TZ1RE024M-C1815, TZ1RE024M-C1816, TZ1RE024M-C2087, TZ1RE024M-R, TZ1RE024PGOR8C, TZ1RE024SR11, TZ1RE024SR11-093861, TZ1RE024SR11-094343, TZ1RE024SR11-C1684, TZ1RE024SR11-C1816, TZ1RE024SR6, TZ1RE024SR6-C1638, TZ1RE024SR6-C1677, TZ1RE110M, TZ1RE110M-C1684, TZ1RE110M-R, TZ1RE110PGOR8C, TZ1RE110SR6, TZ1RE220M, TZ1RE220M-C1684, TZ1RE220SR6
Item specifics
- Series:
- TZ Series
- Locking principle:
- Mechanical Lock, Solenoid Release
- Number of contacts:
- 2
- Locking force:
- 1500 N
- Material:
- Anodized die-cast alloy
- Connection:
- M20 or Plug connector BHA8/SR11/SR6
- Security level:
- IP65 / IP67
- Certifications:
- EAC, GL, UL, CCC, DGUV
Review
Description
For Euchner TZ Series with Door and Lock Monitoring 2 Contacts Mechanical Lock Solenoid Release Safety Switch Replacement Parameter
Brand | From network | DADISICK |
|
Models | TZ1LE024M | TZ1RE024M-089471 |
OX-W3 series |
TZ1LE024M-089470 | TZ1RE024M-C1623 | ||
TZ1LE024M-C1623 | TZ1RE024M-C1684 | ||
TZ1LE024M-C1684 | TZ1RE024M-C1815 | ||
TZ1LE024M-C1815 | TZ1RE024M-C1816 | ||
TZ1LE024M-C1816 | TZ1RE024M-C2087 | ||
TZ1LE024M-C2087 | TZ1RE024M-R | ||
TZ1LE024M-R | TZ1RE024PGOR8C | ||
TZ1LE024PGOR8C | TZ1RE024SR11 | ||
TZ1LE024SR11 | TZ1RE024SR11-093861 | ||
TZ1LE024SR11-093860 | TZ1RE024SR11-094343 | ||
TZ1LE024SR11-C1684 | TZ1RE024SR11-C1684 | ||
TZ1LE024SR11-C1816 | TZ1RE024SR11-C1816 | ||
TZ1LE024SR6 | TZ1RE024SR6 | ||
TZ1LE024SR6-C1638 | TZ1RE024SR6-C1638 | ||
TZ1LE024SR6-C1677 | TZ1RE024SR6-C1677 | ||
TZ1LE110M | TZ1RE110M | ||
TZ1LE110M-R | TZ1RE110M-C1684 | ||
TZ1LE110PGOR8C | TZ1RE110M-R | ||
TZ1LE110SR6 | TZ1RE110PGOR8C | ||
TZ1LE220M | TZ1RE110SR6 | ||
TZ1LE220M-C1684 | TZ1RE220M | ||
TZ1LE220SR6 | TZ1RE220M-C1684 | ||
TZ1RE024M | TZ1RE220SR6 | ||
Sensor principle | Closed-circuit current principle | Electro-mechanical | |
Locking principle | Mechanical Lock, Solenoid Release | Mechanical Lock, Solenoid Release | |
Number of contacts | 2 | 2 | |
Locking force | 1500 N | 1300 N | |
Approach speed | 20 m/min | 0.05 - 0.5 m/s | |
Actuation frequency | max. 1200 1/h | Up to 20 operations/min | |
Material | Anodized die-cast alloy | Metal, PA66 flame retardant | |
Connector | M20 or Plug connector BHA8/SR11/SR6 | M20 or 1.5 m cable | |
Power consumption | 10 W | 4.8 W | |
Switching voltage | 24 V DC | 24 V DC | |
Rated operating current (voltage) | AC-15: 4 A / 230 V
DC-13: 4 A / 24 V | AC-15: 3 A / 240 V
DC-13: 2.3 A / 30 V | |
Rated impulse withstand voltage (Uimp) | 1.5 kV, 1.5 kV, 2.5 kV | 2.5 kV | |
Enclosure rating | IP65 / IP67 | IP67 | |
Ambient operating temperature | -25 to 80℃ | -20℃ to 60℃ | |
We are able to reproduce the specific connection configuration of each brand with high level of accuracy. |
Product model display instructions
The brands and specifications shown on this page are for product selection only. Our safety switches is a safety part made by DADISICK, not official brand Euchner's products. DAIDSICK offer replacement for official brand products. We are not the owner of the brands. If you need to buy official brand products, please contact the brand official representative.
Product recommendations
Safety switches OX-W3 series
Mechanical Lock, Solenoid Release Model:
OX-W3-C/C-GC-J, OX-W3-/2C-GC-J,
OX-W3-2C/-GC-J, OX-W3-CO/-GC-J,
OX-W3-O/C-GC-J, OX-W3-/CO-GC-J
FAQ
What is a Safety Interlock Switch?
A safety interlock switch is a device used to ensure the safety of machines or equipment during operation. They are typically used to prevent equipment from starting or running under unsafe conditions, thereby protecting operators and equipment from injury or damage.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.