D4SL Series with Door and Lock monitoring 5 or 6 Contacts Solenoid Lock Mechanical Release Safety Interlock Door Switches Replacement
- Model
- D4SL Series | D4SL-N2EFG-D, D4SL-N4EFG-D, D4SL-N2FFG-DN, D4SL-N2FFG-D, D4SL-N4FFG-D, D4SL-N2NFG-DN, D4SL-N2NFG-D, D4SL-N2NFG-D4N, D4SL-N2NFG-D4, D4SL-N4NFG-DN, D4SL-N4NFG-D, D4SL-N4GFG-DN, D4SL-N4GFG-D, D4SL-N2HFG-DN, D4SL-N2HFG-D, D4SL-N4HFG-DN, D4SL-N4HFG-D, D4SL-N4HFG-D4, D4SL-N4RFG-D
Item specifics
- Series:
- D4SL Series
- Locking principle:
- Solenoid Lock, Mechanical Release
- Number of contacts:
- 5 or 6
- Locking force:
- 1300 N
- Material:
- Plastic Head
- Connection:
- G1/2 or M20
- Security level:
- IP67
- Certifications:
- TÜV, CE, cRUUS, CCC
Review
Description
D4SL Series with Door and Lock monitoring 5 or 6 Contacts Solenoid Lock Mechanical Release Safety Interlock Door Switches Replacement Parameter
Brand | From network | DADISICK |
|
Models | D4SL-N2EFG-D |
OX-W5 series | |
D4SL-N4EFG-D | |||
D4SL-N2FFG-DN | |||
D4SL-N2FFG-D | |||
D4SL-N4FFG-D | |||
D4SL-N2NFG-DN | |||
D4SL-N2NFG-D | |||
D4SL-N2NFG-D4N | |||
D4SL-N2NFG-D4 | |||
D4SL-N4NFG-DN | |||
D4SL-N4NFG-D | |||
D4SL-N4GFG-DN | |||
D4SL-N4GFG-D | |||
D4SL-N2HFG-DN | |||
D4SL-N2HFG-D | |||
D4SL-N4HFG-DN | |||
D4SL-N4HFG-D | |||
D4SL-N4HFG-D4 | |||
D4SL-N4RFG-D | |||
Technical parameters | Sensor principle | Electro-mechanical | Electro-mechanical |
Locking principle | Solenoid Lock, Mechanical Release | Solenoid Lock, Mechanical Release | |
Number of contacts | 5 or 6 | 5 or 6 | |
Locking force | 1300 N | 1300 N | |
Approach speed | 0.05 to 1 m/s | 0.05 - 0.5 m/s | |
Actuation frequency | 5-contact Model: 30 operations minute max. 6-contact Model: 30 operations minute max. | Up to 20 operations/min | |
Material | Plastic Head | Metal, PA66 flame retardant | |
Connector | G1/2 or M20 | M20 or 1.5 m cable | |
Power consumption | — | 4.8 W | |
Switching voltage | 24 V DC | 24 V DC | |
Rated operating current (voltage) | AC-15 1.5 A*1 OR 1 A*2 / 120 V
DC-13 0.22 A / 125 V | AC-15: 3 A / 240 V
DC-13: 2.3 A / 30 V | |
Rated impulse withstand voltage (Uimp) | 1.5 kV, 1.5 kV, 2.5 kV | 2.5 kV | |
Enclosure rating | IP67 | IP67 | |
Ambient operating temperature | -10 to 55℃ | -20℃ to 60℃ | |
We are able to reproduce the specific connection configuration of each brand with high level of accuracy. |
Product model display instructions
The product models displayed on this page are only used to describe and compare the characteristics, specifications, and performance of different products. These models do not represent recommendations or associations for any specific brand or company. When users choose products, please understand and compare the detailed information of each brand's products on your own.
Product recommendations
Safety switches OX-W5 series
Solenoid Lock, Mechanical Release:
OX-W5-2CO/2CO-GD-J
OX-W5-3C/2CO-GD-J
OX-W5-2CO/3C-GD-J
OX-W5-3C/3C-GD-J
FAQ
How do Safety Interlock Switches work?
Safety interlock switches are usually used in conjunction with doors or guards. When the door or guard is not closed or is in an open state, the switch will cut off the circuit, preventing the equipment from starting or running. Once the door or guard is closed, the switch restores the circuit, allowing the equipment to operate normally.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.