Model
UST-M18MS Series | UST-M18MS-TMS-101, UST-M18MS-TMS-603, UST-M18MS-TMS-301, UST-M18MS-TMS-403, UST-M18MS-TMS-711, UST-M18MS-TMS-729, UST-M18MS-TMS-72A, UST-M18MS-TMS-813, UST-M18MS-TMS-839, UST-M18MS-TMS-83A

Item specifics

Series:
UST-M18MS Series
Size:
M18
Sensing Distance:
100...900 mm
Output Method:
PNP / NPN / Analog output
Connection Type:
M12 4-pin / M12 5-pin
Security level:
IP67
Material:
Stainless-steel V2A

Review

Description

UST-M18MS Series Standard Body Diffuse M18 Stainless Steel V2A Ultrasonic Sensors Replacement Parameter

Brand
From network
DADISICK
Models
UST-M18MS-TMS-101
CSB18-1000-J55-E7-V15
UST-M18MS-TMS-603
CSB18-1000-J55-E6-V15
UST-M18MS-TMS-301
CSB18-1000-J55-E2-V15
UST-M18MS-TMS-403
CSB18-1000-J55-E3-V15
UST-M18MS-TMS-711
CSB18-1000-J55-E7-V15
UST-M18MS-TMS-729
CSB18-1000-J55-IUEP-IO-V15
UST-M18MS-TMS-72A
CSB18-1000-J55-IUEP-IO-V15
UST-M18MS-TMS-813
CSB18-1000-J55-E8-V15
UST-M18MS-TMS-839
CSB18-1000-J55-IUEP-IO-V15
UST-M18MS-TMS-83A
CSB18-1000-J55-IUEP-IO-V15
Thread Size
M18
M18
Sensing Distance
100...900 mm
60 mm - 1000 mm
Output Method
NPN or PNP: NO/NC + NO/NC
NPN or PNP: NO/NC
NPN or PNP: NO/NC SYNC/MUX
NPN or PNP: Analog current 4-20 mA
NPN or PNP: Analog voltage 0-10 V
2*NPN or 2*PNP: NO/NC
NPN or PNP: NO/NC
NPN or PNP: Analog current 4-20 mA
NPN or PNP: Analog voltage 0-10 V
Analog + push pull output, support IO-Link
Connector
M12 4-pin / M12 5-pin
M12
Security level
IP67
IP67
Material
Stainless-steel V2A
Nickel plated copper
We are able to reproduce the specific connection configuration of each brand with high level of accuracy.
Product model display instructions
The product models displayed on this page are only used to describe and compare the characteristics, specifications, and performance of different products. These models do not represent recommendations or associations for any specific brand or company. When users choose products, please understand and compare the detailed information of each brand's products on your own.
Product recommendations
DADISICK Ultrasonic sensors CSB18 series
Model: 
CSB18-1000-J55-E7-V15, CSB18-1000-J55-E6-V15, 
CSB18-1000-J55-E2-V15, CSB18-1000-J55-E3-V15, 
CSB18-1000-J55-IUEP-IO-V15, CSB18-1000-J55-E8-V15

FAQ
Please describe the maintenance procedures for ultrasonic sensors.
A: It is important to regularly check the cleanliness of the transducer to avoid dust and dirt from affecting the transmitting and receiving functions of the transducer. It is important to calibrate the sensor on a regular basis to ensure that the measurements are accurate. Following the maintenance guide provided by the manufacturer will ensure the sensor's optimal performance and longevity.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.
Dimensions
Dimensions  (Unit: Mm)
Ultrasonic sensors CSB18 series Dimensions
Reference Curve
DADISICK Ultrasonic sensors CSB18 series Reference Curve
Ultrasonic sensors CSB18 series data sheet
Ultrasonic sensors CSB18 series operation instructions