For ReeR Vision Series 40 mm Resolution 8 m Sensing Distance 310 mm to 1810 mm Protective Height MXL Safety Light Curtain Replacement
- Model
- Vision Series | MXL 304, MXL 454, MXL 604, MXL 754, MXL 904, MXL 1054, MXL 1204, MXL 1354, MXL 1504, MXL 1654, MXL 1804
Item specifics
- Series
- Vision Series
- Resolution:
- 40 mm
- Scanning range:
- 8 m
- Protective field height:
- 310 - 1810 mm
- 2 Safety outputs (OSSD):
- 2 PNP
- Response time:
- 8 - 35 ms
- Connection type:
- M12
- Security level:
- PLe4
Review
Description
For ReeR Vision Series 40 mm Resolution 8 m Sensing Distance 310 mm to 1810 mm Protective Height MXL Safety Light Curtain Replacement Parameter
Brand | From network | DADISICK |
|
Models
|
MXL 304 | QCE08-40-280 2BB |
|
MXL 454 |
QCE12-40-440 2BB | ||
MXL 604 | QCE16-40-600 2BB | ||
MXL 754 | QCE20-40-760 2BB | ||
MXL 904 | QCE24-40-920 2BB | ||
MXL 1054 | QCE28-40-1080 2BB | ||
MXL 1204 | QCE32-40-1240 2BB | ||
MXL 1354 | QCE36-40-1400 2BB | ||
MXL 1504 | QCE38-40-1480 2BB | ||
MXL 1654 | QCE42-40-1640 2BB | ||
MXL 1804 | QCE46-40-1800 2BB | ||
Beam spacing | 40 mm | 40 mm | |
Protected altitude | 310 mm, 460 mm, 610 mm, 760 mm, 910 mm, 1060 mm, 1210 mm, 1360 mm, 1510 mm, 1660 mm, 1810 mm | 280 mm, 440 mm, 600 mm, 760 mm, 920 mm, 1080 mm, 1240 mm, 1400 mm, 1480 mm, 1640 mm, 1800 mm | |
Scanning range | 8 m | 0.3 - 6 m | |
Response time | 8 ms - 35 ms | ≤15 ms | |
Output method | 2 PNP | 2 PNP | |
Reliability and durability | IP65 | IP65 | |
Connector | M12 | M12 | |
Housing cross-section | 45 mm x 35 mm | 30 mm x 30 mm | |
Safety Certificate | CE, TÜV, cULus,RoHS,UKCA | TÜV, UL, CE, RoHS, GB | |
We are able to reproduce the specific connection configuration of each brand with high level of accuracy. |
Product model display instructions
The brands and specifications shown on this page are for product selection only. Our safety light curtain is a safety part made by DADISICK, not official brand ReeR's products. DAIDSICK offer replacement for official brand products. We are not the owner of the brands. If you need to buy official brand products, please contact the brand official representative.
Product recommendations
Model:
QCE08-40-280 2BB, QCE12-40-440 2BB, QCE16-40-600 2BB
QCE20-40-760 2BB, QCE24-40-920 2BB, QCE28-40-1080 2BB
QCE32-40-1240 2BB, QCE36-40-1400 2BB, QCE38-40-1480 2BB
QCE42-40-1640 2BB, QCE46-40-1800 2BB
FAQ
Q: How to choose the output mode of a safety light curtain?
A:
The output mode of a safety light curtain refers to the form in which the safety light curtain converts the signal. There are typically multiple options available, and users can choose based on their specific needs. Here are some common output modes for safety light curtains.
Relay output. This is the most common output mode, where the safety light curtain has a built-in small relay with a set of normally open and normally closed passive output contacts that can be connected to any load.
1. NPN/PNP output: This output mode is commonly used for connecting to digital circuit controllers, where the signal is output in a pulsed manner. Users can select one of the output modes based on their specific needs, and it can be connected to PLCs, PCs, or external relays.
2. Dual NPN output/Dual PNP output: This output mode allows for two load connections, such as PLCs, PCs, or external relays, or can be connected to a safety relay output. It is suitable for various application scenarios.
3. Controller output: The controller can provide the necessary supply for the safety light curtain, and the safety light curtain can direct
to choose the appropriate output mode for a safety light curtain, it is important to consider the specific requirements of different application scenarios. DADISHENG safety light curtains remind you that for situations requiring long-distance signal transmission or remote control, relay output is recommended. For industrial automation applications, NPN/PNP output or controller output can be selected.
Furthermore, users should also consider factors such as safety, stability, and user-friendliness. Regardless of the chosen output, it is crucial to ensure reliability and stability to guarantee the normal operation and safety of the system.
In summary, there are several options for the output mode of a safety light curtain, including relay output, NPN/PNP output, dual NPN output, dual PNP output, and controller output. When selecting the output mode, users should consider the requirements of their specific application scenario and take into account factors such as safety, stability, and user-friendliness.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.