For KEYENCE GL-R Series Safety Light Curtain Replacement 25 mm Resolution | 15 m Operating Range | 140 mm to 1206 mm Protective Height
- Model
- GL-R Series | GL-R08HG, GL-R12HG, GL-R16HG, GL-R20HG, GL-R24HG, GL-R28HG, GL-R32HG, GL-R36HG, GL-R40HG, GL-R44HG, GL-R48HG, GL-R52HG, GL-R56HG, GL-R60HG, GL-R64HG
Item specifics
- Series:
- GL-R Series
- Resolution:
- 25 mm
- Scanning range:
- 0.2 m - 15 m
- Protective field height:
- 140 mm - 1206 mm
- 2 Safety outputs (OSSD):
- 2 PNP
- Response time:
- 6.6 ms - 11.3 ms
- Connection type:
- M12
- Security level:
- PLe4
Review
Description
For KEYENCE GL-R Series Safety Light Curtain Replacement Parameter
Brand | From network | DADISICK |
|
Models
|
GL-R08HG | QT08-20-140-2BD |
|
GL-R12HG | QT14-20-260-2BD | ||
GL-R16HG |
QT16-20-300-2BD | ||
GL-R20HG | QT20-20-380-2BD | ||
GL-R24HG | QT24-20-460-2BD | ||
GL-R28HG | QT28-20-540-2BD | ||
GL-R32HG | QT32-20-620-2BD | ||
GL-R36HG | QT36-20-700-2BD | ||
GL-R40HG | QT40-20-780-2BD | ||
GL-R44HG | QT44-20-860-2BD | ||
GL-R48HG | QT48-20-940-2BD | ||
GL-R52HG | QT52-20-1020-2BD | ||
GL-R56HG | QT56-20-1100-2BD | ||
GL-R60HG | QT60-20-1180-2BD | ||
GL-R64HG | QT64-20-1260-2BD | ||
Beam spacing | 25 mm | 20 mm | |
Protected altitude | 140 mm, 240 mm, 300 mm, 380 mm, 460 mm, 540 mm, 620 mm, 700 mm, 780 mm, 860 mm, 940 mm, 1020 mm, 1100 mm, 1180 mm, 1260 mm | 140 mm, 260 mm, 300 mm, 380 mm, 460 mm, 540 mm, 620 mm, 700 mm, 780 mm, 860 mm, 940 mm, 1020 mm, 1100 mm, 1180 mm, 1260 mm | |
Scanning range | 0.2 m - 15 m | 0.3 m - 15 m | |
Response time | 6.6 ms - 11.3 ms | ≤15 ms | |
Output method | 2 PNP | 2 PNP | |
Reliability and durability | IP65 / IP67 | IP65 | |
Connector | M12 | M16 | |
Housing cross-section | 38 mm × 32 mm | 35 mm × 51 mm | |
Safety Certificate | CE, UL | TÜV, UL, CE, RoHS, GB | |
We are able to reproduce the specific connection configuration of each brand with high level of accuracy. |
Product model display instructions
The brands and specifications shown on this page are for product selection only. Our safety light curtain is a safety part made by DADISICK, not official brand KEYENCE's products. DAIDSICK offer replacement for official brand products. We are not the owner of the brands. If you need to buy official brand products, please contact the brand official representative.
Product recommendations
Model:
QT08-20-140-2BD, QT14-20-260-2BD, QT16-20-300-2BD, QT20-20-380-2BD, QT24-20-460-2BD, QT28-20-540-2BD, QT32-20-620-2BD, QT36-20-700-2BD, QT40-20-780-2BD, QT44-20-860-2BD, QT48-20-940-2BD, QT52-20-1020-2BD, QT56-20-1100-2BD, QT60-20-1180-2BD, QT64-20-1260-2BD
FAQ
What are the requirements for the working environment of safety light curtains?
The requirements for the working environment of safety light curtains include:
1.Temperature: The environmental temperature should be within the range of -10℃ to 55℃. Excessive temperatures, either too high or too low, may affect the normal operation of the safety light curtain.
2.Humidity: The air relative humidity should not exceed 95%. High humidity may cause condensation on the optical components, affecting their performance.
3.Media: The air should be free of media that can trigger explosions or corrode metals and damage insulation.
4.Vibration: The vibration amplitude and corresponding frequency should conform to national standards. Excessive vibration may damage internal components of the safety light curtain.
5.Lighting: Direct sunlight or other strong light sources should be avoided, as they may interfere with the detection accuracy of the safety light curtain.
6.Dust and dirt: Environments with excessive dust or dirt may accumulate on the optical surfaces of the safety light curtain, reducing its transmission efficiency. Regular cleaning and maintenance are required.
7.Reflective surfaces: Surfaces that can reflect light should be avoided in the vicinity of the safety light curtain, as reflected light may interfere with its operation.
8.Interference sources: The installation location should be free of interference sources that can affect the signal transmission of the safety light curtain, such as electromagnetic fields.
9.Space: The installation space should allow for the correct alignment and adjustment of the transmitter and receiver units of the safety light curtain.
It is important to note that the specific requirements for the working environment of safety light curtains may vary depending on the model, manufacturer, and intended application. It is recommended to consult the manufacturer's specifications and installation instructions for detailed information.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.