For Leuze MLC 510 / 520 Series Light Curtain Sensor Replacement 90 mm Resolution 20 Meters Sensing Distance 450 mm to 1800 mm Protection Height
- Model
- MLC 510 / 520 Series | MLC500T90-450MG, MLC520R90-450MG, MLC500T90-600MG, MLC520R90-600MG, MLC500T90-750MG, MLC520R90-750MG, MLC500T90-900MG, MLC520R90-900MG, MLC500T90-1050MG, MLC520R90-1050MG, MLC500T90-1200MG, MLC520R90-1200MG, MLC500T90-1350MG, MLC520R90-1350MG, MLC500T90-1500MG, MLC520R90-1500MG, MLC500T90-1650MG, MLC520R90-1650MG, MLC500T90-1800MG, MLC520R90-1800MG
Item specifics
- Series:
- MLC 510 / 520 Series
- Resolution:
- 90 mm
- Scanning range:
- 0 - 20 m
- Protective field height:
- 450 - 1800 mm
- 2 Safety outputs (OSSD):
- 2 PNP
- Response time:
- 3 - 7 ms
- Connection type:
- M12
- Security level:
- PLe4
Review
Description
For Leuze MLC 510 / 520 Series Light Curtain Sensor Replacement 90 mm Resolution 20 Meters Sensing Distance 450 mm to 1800 mm Protection Height Parameter
Brand | Transmitter | Receiver | DADISICK |
||
Models | MLC500T90-450MG | MLC520R90-450MG | QT06-80-400 2BE | ||
MLC500T90-600MG | MLC520R90-600MG | QT08-80-560 2BE | |||
MLC500T90-750MG | MLC520R90-750MG | QT10-80-720 2BE | |||
MLC500T90-900MG | MLC520R90-900MG | QT12-80-880 2BE | |||
MLC500T90-1050MG | MLC520R90-1050MG | QT14-80-1040 2BE | |||
MLC500T90-1200MG | MLC520R90-1200MG | QT16-80-1200 2BE | |||
MLC500T90-1350MG | MLC520R90-1350MG | QT18-80-1360 2BE | |||
MLC500T90-1500MG | MLC520R90-1500MG | QT20-80-1520 2BE | |||
MLC500T90-1650MG | MLC520R90-1650MG | QT22-80-1680 2BE | |||
MLC500T90-1800MG | MLC520R90-1800MG | QT24-80-1840 2BE | |||
Beam spacing | 90 mm | 80 mm | |||
Protected altitude | 450 mm, 600 mm, 750 mm, 900 mm, 1050 mm, 1200 mm, 1350 mm, 1500 mm, 1650 mm, 1800 mm | 400 mm, 560 mm, 720 mm, 880 mm, 1040 mm, 1200 mm, 1360 mm, 1520 mm, 1680 mm, 1840 mm | |||
Scanning range | 0 - 20 m | 0.3 - 20 m | |||
Response time | 3 - 7 ms | ≤15 ms | |||
Output method | 2 PNP | 2 PNP | |||
Reliability and durability | IP65 | IP65 | |||
Connector | M12 | M16 | |||
Housing cross-section | 53 mm x 29 mm | 51 mm x 35 mm | |||
Safety Certificate | KCs, TÜV Süd, c TÜV NRTL US, c UL US, PLe4 | TUV, UL, CE, RoSH, GB | |||
We are able to reproduce the specific connection configuration of each brand with high level of accuracy. |
Product model display instructions
The brands and specifications shown on this page are for product selection only. Our safety light curtain is a safety part made by DADISICK, not official brand Leuze's products. DAIDSICK offer replacement for official brand products. We are not the owner of the brands. If you need to buy official brand products, please contact the brand official representative.
Product recommendations
Model:
QT06-80-400 2BE, QT08-80-560 2BE, QT10-80-720 2BE
QT12-80-880 2BE, QT14-80-1040 2BE, QT16-80-1200 2BE
QT18-80-1360 2BE, QT20-80-1520 2BE, QT20-80-1520 2BE
QT22-80-1680 2BE, QT24-80-1840 2BE
FAQ
1.Is the new light curtain compatible with the existing system?
We provide 1:1 customized replacement of the original light curtain data connector, with compatibility including electrical interfaces, communication protocols, and mechanical installation. Please compare the specifications of existing light curtains with ours, or contact our technical support team to help you find a compatible replacement model.
2. What tests should I perform after installing a new light screen?
We suggest conducting functional testing and security verification to ensure that the new light curtain can function properly. The testing items include detection range, response time, and alarm function.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.