For RIKEN OPTECH RPX414 Series 9 mm Resolution 9 m Sensing Distance 207 mm to 972 mm Protective Height Safety Light Curtain Replacement
For RIKEN OPTECH RPX414 Series 9 mm Resolution 9 m Sensing Distance 207 mm to 972 mm Protective Height Safety Light Curtain Replacement
For RIKEN OPTECH RPX414 Series 9 mm Resolution 9 m Sensing Distance 207 mm to 972 mm Protective Height Safety Light Curtain Replacement
For RIKEN OPTECH RPX414 Series 9 mm Resolution 9 m Sensing Distance 207 mm to 972 mm Protective Height Safety Light Curtain Replacement
For RIKEN OPTECH RPX414 Series 9 mm Resolution 9 m Sensing Distance 207 mm to 972 mm Protective Height Safety Light Curtain Replacement
For RIKEN OPTECH RPX414 Series 9 mm Resolution 9 m Sensing Distance 207 mm to 972 mm Protective Height Safety Light Curtain Replacement
Model
RPX414 Series | RPX414-225X4FL1, RPX414-297X4FL1, RPX414-360X4FL1, RPX414-423X4FL1, RPX414-486X4FL1, RPX414-549X4FL1, RPX414-612X4FL1, RPX414-675X4FL1, RPX414-738X4FL1, RPX414-801X4FL1, RPX414-864X4FL1, RPX414-927X4FL1, RPX414-990X4FL1

Item specifics

Series
RPX414 Series
Resolution:
9 mm
Scanning range:
0.2 - 9 m
Protective field height:
207 - 972 mm
2 Safety outputs (OSSD):
2 PNP
Response time:
10 - 27.5 ms
Connection type:
M12
Security level:
PLe4

Review

Description

For RIKEN OPTECH RPX414 Series 9 mm Resolution 9 m Sensing Distance 207 mm to 972 mm Protective Height Safety Light Curtain Replacement Parameter
Brand
From network
DADISICK
Models
RPX414-225X4FL1
QM22-10-210 2BC
RPX414-297X4FL1
QM28-10-270 2BC
RPX414-360X4FL1
QM36-10-350 2BC
RPX414-423X4FL1
QM42-10-405 2BC
RPX414-486X4FL1
QM48-10-468 2BC
RPX414-549X4FL1
QM54-10-530 2BC
RPX414-612X4FL1
QM60-10-590 2BC
RPX414-675X4FL1
QM66-10-650 2BC
RPX414-738X4FL1
QM72-10-710 2BC
RPX414-801X4FL1
QM80-10-790 2BC
RPX414-864X4FL1
QM86-10-850 2BC
RPX414-927X4FL1
QM92-10-910 2BC
RPX414-990X4FL1
QM98-10-970 2BC
Beam spacing
9 mm
10 mm
Protected altitude
207 mm, 279 mm, 342 mm, 405 mm, 468 mm, 531 mm, 594 mm, 657 mm, 720 mm, 783 mm, 846 mm, 909 mm, 972 mm
210 mm, 270 mm, 350 mm, 405 mm, 468 mm, 530 mm, 590 mm, 650 mm, 710 mm, 790 mm, 850 mm, 910 mm, 970 mm
Scanning range
0.2 - 9 m
0.3 - 10 m
Response time
10 ms - 27.5 ms
≤15 ms
Output method
2 PNP
2 PNP
Reliability and durability
IP65
IP65
Connector
M12
M12
Housing cross-section
24 mm x 29 mm
36 mm x 36 mm
Safety Certificate
CE,UL
TÜV, UL, CE, RoHS, GB
We are able to reproduce the specific connection configuration of each brand with high level of accuracy.
Product model display instructions
The brands and specifications shown on this page are for product selection only. Our safety light curtain is a safety part made by DADISICK, not official brand RIKEN OPTECH's products. DAIDSICK offer replacement for official brand products. We are not the owner of the brands. If you need to buy official brand products, please contact the brand official representative.
Product recommendations
DADISICK QM Series Machine Light Curtains
Model:
QM22-10-210 2BC, QM28-10-270 2BC, QM36-10-350 2BC
QM42-10-405 2BC, QM48-10-468 2BC, QM54-10-530 2BC
QM60-10-590 2BC, QM66-10-650 2BC, QM72-10-710 2BC
QM80-10-790 2BC, QM86-10-850 2BC, QM92-10-910 2BC
QM98-10-970 2BC





FAQ
Q:How to determine if a safety light curtain is working properly?
Safety light curtains are also known as safety light screens, safety light curtain sensors, infrared safety light curtains, photoelectric protectors, infrared photoelectric protectors, punch press photoelectric protection devices, etc.

How to determine if a safety light curtain is in working mode?

Many customers may have doubts when using a light curtain for the first time, wondering if it is installed correctly and if it is in normal working mode.

Because the purpose of a safety light curtain is to protect personal safety, it must be taken seriously. So how can we determine if a safety light curtain is in working mode?

When the safety light curtain is powered on, the emitter will flash three times and then remain on, indicating that it has entered the working mode. The receiver will have red and green lights flashing three times when powered on, indicating that it has also entered the working mode.
What are the conditions for the safety light curtain to be working properly?

When the emitter and receiver are in working condition, the emitter's red light remains on, and the receiver's green light is illuminated. When the light curtain is obstructed, there is no change in the emitter's indicator light, but the receiver's light changes from green to red, and the digital display shows the number of blocked light beams. When there is no obstruction, the receiver returns to its normal state with a constant green light.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.
Safety Light Curtain Wiring Diagrams/Dimensional Drawings
safety light curtain Cable description
DADISICK Safety Light Curtain Cable Description
signal output selection (actual output of transistor working normally)
DADISICK Safety Light Curtain Signal Output Selection
NPN output wiring diagram
DADISICK Safety Light Curtain NPN Output Wiring Diagram
PNP output wiring diagram
DADISICK Safety Light Curtain PNP Output Wiring Diagram
safety light curtain Dimension
DADISICK Safety Light Curtain Dimension

recommend