For OMRON F3SJ-A Advanced Safety Light Curtain Replacement 2PNP Output 50 mm Resolution | 9 m Operating Range | 270 mm to 2470 mm Protective Height
- Model
- F3SJ-A Series | F3SJ-A0270P55, F3SJ-A0320P55, F3SJ-A0370P55, F3SJ-A0470P55, F3SJ-A0570P55, F3SJ-A0620P55, F3SJ-A0720P55, F3SJ-A0770P55, F3SJ-A0870P55, F3SJ-A0920P55, F3SJ-A0970P55, F3SJ-A1020P55, F3SJ-A1120P55, F3SJ-A1170P55, F3SJ-A1270P55, F3SJ-A1320P55, F3SJ-A1420P55, F3SJ-A1570P55, F3SJ-A1770P55, F3SJ-A1920P55, F3SJ-A2070P55, F3SJ-A2220P55, F3SJ-A2370P55, F3SJ-A2470P55
Item specifics
- Series:
- F3SJ-A Series
- Resolution:
- 50 mm
- Scanning range:
- 0.2 m - 9 m
- Protective field height:
- 270 mm - 2470 mm
- 2 Safety outputs (OSSD):
- 2 PNP
- Response time:
- 10 ms - 13 ms
- Connection type:
- M12
- Security level:
- PLe4
Review
Description
For OMRON F3SJ-A Advanced Safety Light Curtain Replacement Parameter
Brand | From network | DADISICK |
|
Models
|
F3SJ-A0270P55 | QT08-40-280-2BC |
|
F3SJ-A0320P55 | QT10-40-360-2BC | ||
F3SJ-A0370P55 |
QT10-40-360-2BC | ||
F3SJ-A0470P55 | QT12-40-440-2BC | ||
F3SJ-A0570P55 | QT16-40-600-2BC | ||
F3SJ-A0620P55 | QT16-40-600-2BC | ||
F3SJ-A0720P55 | QT18-40-680-2BC | ||
F3SJ-A0770P55 | QT20-40-760-2BC | ||
F3SJ-A0870P55 | QT22-40-840-2BC | ||
F3SJ-A0920P55 | QT24-40-920-2BC | ||
F3SJ-A0970P55 | QT26-40-1000-2BC | ||
F3SJ-A1020P55 | QT26-40-1000-2BC | ||
F3SJ-A1120P55 | QT28-40-1080-2BC | ||
F3SJ-A1170P55 | QT30-40-1160-2BC | ||
F3SJ-A1270P55 | QT32-40-1240-2BC | ||
F3SJ-A1320P55 | QT34-40-1320-2BC | ||
F3SJ-A1420P55 | QT36-40-1400-2BC | ||
F3SJ-A1570P55 | QT40-40-1560-2BC | ||
F3SJ-A1770P55 | QT46-40-1800-2BC | ||
F3SJ-A1920P55 | QT48-40-1880--2BC | ||
F3SJ-A2070P55 | QT52-40-2040-2BC | ||
F3SJ-A2220P55 | QT56-40-2200-2BC | ||
F3SJ-A2370P55 | QT60-40-2360-2BC | ||
F3SJ-A2470P55 | QT62-40-2440-2BC | ||
Beam spacing | 50 mm | 40 mm | |
Protected altitude | 270 mm, 320 mm, 370 mm, 470 mm, 570 mm, 620 mm, 720 mm, 770 mm, 870 mm, 920 mm, 970 mm, 1020 mm, 1120 mm, 1170 mm, 1270 mm, 1320 mm, 1420 mm, 1570 mm, 1770 mm, 1920 mm, 2070 mm, 2220 mm, 2370 mm, 2470 mm | 280 mm, 360 mm, 360 mm, 440 mm, 600 mm, 600 mm, 680 mm, 760 mm, 840 mm, 920 mm, 1000 mm, 1000 mm, 1080 mm, 1160 mm, 1240 mm, 1320 mm, 1400 mm, 1560 mm, 1800 mm, 1880 mm, 2040 mm, 2200 mm, 2360 mm, 2440 mm | |
Scanning range | 0.2 m - 9 m | 0.3 m - 10 m | |
Response time | 10 ms - 13 ms | ≤15 ms | |
Output method | 2 PNP | 2 PNP | |
Reliability and durability | IP65 | IP65 | |
Connector | M12 | M16 | |
Housing cross-section | 30 mm × 26 mm | 35 mm × 51 mm | |
Safety Certificate | CE, TÜV, UL, S-Mark | TÜV, UL, CE, RoHS, GB | |
We are able to reproduce the specific connection configuration of each brand with high level of accuracy. |
Product model display instructions
The brands and specifications shown on this page are for product selection only. Our safety light curtain is a safety part made by DADISICK, not official brand OMRON's products. DAIDSICK offer replacement for official brand products. We are not the owner of the brands. If you need to buy official brand products, please contact the brand official representative.
Product recommendations
Model:
QT08-40-280-2BC, QT10-40-360-2BC, QT10-40-360-2BC, QT12-40-440-2BC, QT16-40-600-2BC, QT16-40-600-2BC, QT18-40-680-2BC, QT20-40-760-2BC, QT22-40-840-2BC, QT24-40-920-2BC, QT26-40-1000-2BC, QT26-40-1000-2BC, QT28-40-1080-2BC, QT30-40-1160-2BC, QT32-40-1240-2BC, QT34-40-1320-2BC, QT36-40-1400-2BC, QT40-40-1560-2BC, QT46-40-1800-2BC, QT48-40-1880--2BC, QT52-40-2040-2BC, QT56-40-2200-2BC, QT60-40-2360-2BC, QT62-40-2440-2BC
FAQ
After installing the new light curtain, what tests should I conduct?
We recommend conducting functional tests and safety validations to ensure the new light curtain operates properly. Test items include detection range, response time, and alarm functions, among others.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.