Model
F3SG-SR Series | F3SG-4SRA0160-25, F3SG-4SRA0200-25-F, F3SG-4SRA0240-25, F3SG-4SRA0280-25-F, F3SG-4SRA0320-25, F3SG-4SRA0360-25-F, F3SG-4SRA0400-25, F3SG-4SRA0440-25-F, F3SG-4SRA0480-25, F3SG-4SRA0520-25-F, F3SG-4SRA0560-25, F3SG-4SRA0600-25-F, F3SG-4SRA0640-25, F3SG-4SRA0680-25-F, F3SG-4SRA0720-25, F3SG-4SRA0760-25-F, F3SG-4SRA0800-25, F3SG-4SRA0840-25-F, F3SG-4SRA0880-25, F3SG-4SRA0920-25-F, F3SG-4SRA0960-25, F3SG-4SRA1000-25-F, F3SG-4SRA1040-25, F3SG-4SRA1120-25, F3SG-4SRA1200-25, F3SG-4SRA1280-25, F3SG-4SRA1360-25, F3SG-4SRA1440-25

Item specifics

Series:
F3SG-SR Series
Resolution:
20 mm
Scanning range:
20 m
Protective field height:
160 mm - 1440 mm
2 Safety outputs (OSSD):
2 PNP
Response time:
8 ms - 13 ms
Connection type:
M12
Security level:
PLe4

Review

Description

For OMRON F3SG-SR Series Safety Light Curtain Replacement Parameter
Brand
From network
DADISICK
Models
F3SG-4SRA0160-25
QT08-20-140-2BE
F3SG-4SRA0200-25-F
QT10-20-180-2BE
F3SG-4SRA0240-25
QT12-20-220-2BE
F3SG-4SRA0280-25-F
QT14-20-260-2BE
F3SG-4SRA0320-25
QT16-20-300-2BE
F3SG-4SRA0360-25-F
QT18-20-340-2BE
F3SG-4SRA0400-25
QT20-20-380-2BE
F3SG-4SRA0440-25-F
QT22-20-420-2BE
F3SG-4SRA0480-25
QT24-20-460-2BE
F3SG-4SRA0520-25-F
QT26-20-500-2BE
F3SG-4SRA0560-25
QT28-20-540-2BE
F3SG-4SRA0600-25-F
QT30-20-580-2BE
F3SG-4SRA0640-25
QT32-20-620-2BE
F3SG-4SRA0680-25-F
QT34-20-660-2BE
F3SG-4SRA0720-25
QT36-20-700-2BE
F3SG-4SRA0760-25-F
QT38-20-740-2BE
F3SG-4SRA0800-25
QT40-20-780-2BE
F3SG-4SRA0840-25-F
QT42-20-820-2BE
F3SG-4SRA0880-25
QT44-20-860-2BE
F3SG-4SRA0920-25-F
QT46-20-900-2BE
F3SG-4SRA0960-25
QT48-20-940-2BE
F3SG-4SRA1000-25-F
QT50-20-980-2BE
F3SG-4SRA1040-25
QT52-20-1020-2BE
F3SG-4SRA1120-25
QT56-20-1100-2BE
F3SG-4SRA1200-25
QT60-20-1180-2BE
F3SG-4SRA1280-25
QT64-20-1260-2BE
F3SG-4SRA1360-25
QT68-20-1340-2BE
F3SG-4SRA1440-25
QT72-20-1420-2BE
Beam spacing
20 mm
20 mm
Protected altitude
160 mm, 200 mm, 240 mm, 280 mm, 
320 mm, 360 mm, 400 mm, 440 mm, 
480 mm, 520 mm, 560 mm, 600 mm, 
640 mm, 680 mm, 720 mm, 760 mm, 
800 mm, 840 mm, 880 mm, 920 mm, 
960 mm, 1000 mm, 1040 mm, 1120 mm, 
1200 mm, 1280 mm, 1360 mm, 1440 mm
140 mm, 180 mm, 220 mm, 260 mm, 
300 mm, 340 mm, 380 mm, 420 mm, 
460 mm, 500 mm, 540 mm, 580 mm, 
620 mm, 660 mm, 700 mm, 740 mm, 
780 mm, 820 mm, 860 mm, 900 mm, 
940 mm, 980 mm, 1020 mm, 1100 mm, 
1180 mm, 1260 mm, 1340 mm, 1420 mm
Scanning range
20 m
0.3 m - 20 m
Response time
8 ms - 13 ms
≤15 ms
Output method
2 PNP
2 PNP
Reliability and durability
IP65 / IP67
IP65
Connector
M12
M16
Housing cross-section
46.7 mm × 32 mm
35 mm × 51 mm
Safety Certificate
CE, TÜV, UL
TÜV, UL, CE, RoHS, GB
We are able to reproduce the specific connection configuration of each brand with high level of accuracy.
Product model display instructions
The brands and specifications shown on this page are for product selection only. Our safety light curtain is a safety part made by DADISICK, not official brand OMRON's products. DAIDSICK offer replacement for official brand products. We are not the owner of the brands. If you need to buy official brand products, please contact the brand official representative.
Product recommendations
DADISICK Safety Light Curtains
Model:
QT08-20-140-2BE, QT10-20-180-2BE, QT12-20-220-2BE, QT14-20-260-2BE, QT16-20-300-2BE, QT18-20-340-2BE, QT20-20-380-2BE, QT22-20-420-2BE, QT24-20-460-2BE, QT26-20-500-2BE, QT28-20-540-2BE, QT30-20-580-2BE, QT32-20-620-2BE, QT34-20-660-2BE, QT36-20-700-2BE, QT38-20-740-2BE, QT40-20-780-2BE, QT42-20-820-2BE, QT44-20-860-2BE, QT46-20-900-2BE, QT48-20-940-2BE, QT50-20-980-2BE, QT52-20-1020-2BE, QT56-20-1100-2BE, QT60-20-1180-2BE, QT64-20-1260-2BE, QT68-20-1340-2BE, QT72-20-1420-2BE

FAQ
How does the performance of safety light curtains hold up under conditions such as dust, moisture, and other environmental factors?
The protection level (IP code) of safety light curtains is an important indicator, representing the product's ability to resist dust and water. For applications with harsh environmental conditions, safety light curtains with higher protection levels can be selected to ensure they can withstand dust and moisture to a certain extent. Generally, the higher the protection level, the better the performance of the light curtains in harsh environments.

However, even with a higher protection level, safety light curtains may still be affected by factors such as dust and moisture. For example, excessive dust or dirt covering the light curtains may block some beams, leading to a decrease in detection accuracy. Additionally, moisture may cause the internal electronic components of the light curtains to become damp, thereby affecting their performance.

To address these challenges, some measures can be taken to improve the performance of safety light curtains in harsh environments. For instance, regularly clean the surface of the light curtains to ensure they are in good working condition; in humid environments, choose light curtains with moisture-resistant features or implement other moisture-proof measures; in environments with a lot of dust, select light curtains with dust-proof features or add dust covers and other protective measures.

Furthermore, the design and selection of safety light curtains are also crucial. When selecting, choose light curtains with appropriate parameters such as resolution, detection distance, and response time based on the actual application requirements. Additionally, consider factors such as the communication interface, ease of installation and maintenance to ensure they can be effectively integrated with other equipment and reduce the operating costs of the system.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.
Safety Light Curtain Wiring Diagrams/Dimensional Drawings
safety light curtain Cable description
DADISICK Safety Light Curtain Cable Description
signal output selection (actual output of transistor working normally)
DADISICK Light Curtain Signal Output Selection
NPN output wiring diagram
DADISICK Light Curtain NPN Output Wiring Diagram
PNP output wiring diagram
DADISICK Light Curtain PNP Output Wiring Diagram
safety light curtain Dimension
DADISICK Safety Light Curtain Dimension
Safety-light-curtain QT Series Data Sheet
Safety-light-curtain QT Series User Manual

recommend