Model
LS4 Series | LS4ER/50-015, LS4ER/50-015B, LS4ER/50-015F, LS4ER/50-015M, LS4ER/50-015S, LS4ER/50-030, LS4ER/50-030B, LS4ER/50-030F, LS4ER/50-030M, LS4ER/50-030S, LS4ER/50-045, LS4ER/50-045B, LS4ER/50-045F, LS4ER/50-045M, LS4ER/50-045S, LS4ER/50-060, LS4ER/50-060B, LS4ER/50-060F, LS4ER/50-060M, LS4ER/50-060S, LS4ER/50-075, LS4ER/50-075B, LS4ER/50-075F, LS4ER/50-075M, LS4ER/50-075S, LS4ER/50-090, LS4ER/50-090B, LS4ER/50-090F, LS4ER/50-090M, LS4ER/50-090S, LS4ER/50-105, LS4ER/50-105B, LS4ER/50-105F, LS4ER/50-105M, LS4ER/50-105S, LS4ER/50-120, LS4ER/50-120B, LS4ER/50-120F, LS4ER/50-120M, LS4ER/50-120S, LS4ER/50-135, LS4ER/50-135B, LS4ER/50-135F, LS4ER/50-135M, LS4ER/50-135S, LS4ER/50-150, LS4ER/50-150B, LS4ER/50-150F, LS4ER/50-150M, LS4ER/50-150S

Item specifics

Series:
LS4 Series
Resolution:
50mm
Scanning range:
0-12m
Protective field height:
160-1510mm
2 Safety outputs (OSSD):
2 PNP
Response time:
3-11ms
Connection type:
M12
Security level:
UL, CE, TÜV, Type 4

Review

Description

For Datasensing LS4 Series 50mm Resolution 12m Sensing Distance 160mm to 1510mm Protection Height LS4ER Machine Safety Devices Replacement Parameter
Brand
From network
DADISICK
Models
LS4ER/50-015
QT06-40-200 2BD
LS4ER/50-015B
LS4ER/50-015F
LS4ER/50-015M
LS4ER/50-015S
LS4ER/50-030
QT10-40-360 2BD
LS4ER/50-030B
LS4ER/50-030F
LS4ER/50-030M
LS4ER/50-030S
LS4ER/50-045
QT12-40-440 2BD
LS4ER/50-045B
LS4ER/50-045F
LS4ER/50-045M
LS4ER/50-045S
LS4ER/50-060
QT16-40-600 2BD
LS4ER/50-060B
LS4ER/50-060F
LS4ER/50-060M
LS4ER/50-060S
LS4ER/50-075
QT20-40-760 2BD
LS4ER/50-075B
LS4ER/50-075F
LS4ER/50-075M
LS4ER/50-075S
LS4ER/50-090
QT24-40-920 2BD
LS4ER/50-090B
LS4ER/50-090F
LS4ER/50-090M
LS4ER/50-090S
LS4ER/50-105
QT28-40-1080 2BD
LS4ER/50-105B
LS4ER/50-105F
LS4ER/50-105M
LS4ER/50-105S
LS4ER/50-120
QT32-40-1240 2BD
LS4ER/50-120B
LS4ER/50-120F
LS4ER/50-120M
LS4ER/50-120S
LS4ER/50-135
QT36-40-1400 2BD
LS4ER/50-135B
LS4ER/50-135F
LS4ER/50-135M
LS4ER/50-135S
LS4ER/50-150
QT40-40-1560 2BD
LS4ER/50-150B
LS4ER/50-150F
LS4ER/50-150M
LS4ER/50-150S
Beam spacing
50mm
40mm
Protected altitude
160mm, 310mm, 460mm, 610mm, 760mm, 910mm, 1060mm, 1210mm, 1360mm, 1510mm
200mm, 360mm, 440mm, 600mm, 760mm, 920mm, 1080mm, 1240mm, 1400mm, 1560mm
Scanning range
0-12m
0.3-15m
Response time
3-11ms
≤15ms
Output method
2 PNP
2 PNP
Reliability and durability
IP65, IP67
IP65
Connector
M12
M16
Housing cross-section
28 x 30mm
51 x 35mm
Safety Certificate
UL, CE, TÜV, Type 4
TUV, UL, CE, RoSH, GB
We are able to reproduce the specific connection configuration of each brand with high level of accuracy.
Product model display instructions
The brands and specifications shown on this page are for product selection only. Our safety light curtain is a safety part made by DADISICK, not official brand Datasensing's products. DAIDSICK offer replacement for official brand products. We are not the owner of the brands. If you need to buy official brand products, please contact the brand official representative.
Product recommendations
DADISICK Laser Curtain Sensor
Model:
QT06/40-200 2BD, QT10/40-360 2BD, QT12/40-440 2BD, QT16/40-600 2BD, QT20/40-760 2BD, QT24/40-920 2BD, QT28/40-1080 2BD, QT32/40-1240 2BD, QT36/40-1400 2BD, QT40/40-1560 2BD


FAQ
1. Please confirm whether the supplier provides training and documentation for installation and operation.
Yes, we provide installation and operating instructions, as well as safety procedures. Additionally, training services can be requested to ensure that your team is adequately equipped to install and maintain your new light curtain.
2. Please advise me on the long-term maintenance requirements for my new light curtain.
We are pleased to offer long-term technical support and spare parts supply. It is important to ensure that a proper maintenance program is in place and that the status of your light curtains is checked regularly. Our technical support team is available to assist you with any queries you may have.
3. Do you provide OEM services for safety light curtain sensors?
Yes, we offer a comprehensive range of OEM services, including customized product options and laser marking. Our team works closely with our customers to gain a deep understanding of their unique requirements and provide them with tailored solutions. We can adapt our products to suit the specific requirements of different industrial applications, whether that be through customizing sensor sizes or integrating specific features.
4. Please confirm whether the new light curtain is compatible with the existing system.
We can provide a customized 1:1 replacement of the original light curtain data connector. Compatibility is guaranteed for electrical interfaces, communication protocols, and mechanical mounting. Please review the specifications to determine if your existing light curtain is compatible with ours. If you have any questions, please contact our technical support team.
5. Please advise as to the tests that should be performed after the installation of a new light curtain.
It is recommended that functional tests and safety verifications be performed to ensure that the new light curtain is working properly. Tests should be conducted to verify the detection range, response time, and alarm function.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.
Safety Light Curtain Wiring Diagrams/Dimensional Drawings
safety light curtain Cable description
Safety Light Curtain Sensor Cable Description
signal output selection (actual output of transistor working normally)
Security Light Curtain Signal Output Selection
NPN output wiring diagram
Industrial Light Curtain NPN Output Wiring Diagram
PNP output wiring diagram
Infrared Light Curtain PNP Output Wiring Diagram
safety light curtain Dimension
DADISICK Light Beam Curtain Dimension
Safety-light-curtain QT series-data sheet
Safety-light-curtain QT series user manual

recommend