For Euchner LCA 2 Series Safety Light Curtain Replacement 50 mm Resolution | 12 m Operating Range | 160 mm to 1810 mm Protective Height
For Euchner LCA 2 Series Safety Light Curtain Replacement 50 mm Resolution | 12 m Operating Range | 160 mm to 1810 mm Protective Height
For Euchner LCA 2 Series Safety Light Curtain Replacement 50 mm Resolution | 12 m Operating Range | 160 mm to 1810 mm Protective Height
For Euchner LCA 2 Series Safety Light Curtain Replacement 50 mm Resolution | 12 m Operating Range | 160 mm to 1810 mm Protective Height
For Euchner LCA 2 Series Safety Light Curtain Replacement 50 mm Resolution | 12 m Operating Range | 160 mm to 1810 mm Protective Height
For Euchner LCA 2 Series Safety Light Curtain Replacement 50 mm Resolution | 12 m Operating Range | 160 mm to 1810 mm Protective Height
Model
LCA 2 Series | LCA-2TR-50-160, LCA-2TR-50-310, LCA-2TR-50-460, LCA-2TR-50-610, LCA-2TR-50-760, LCA-2TR-50-910, LCA-2TR-50-1060, LCA-2TR-50-1210, LCA-2TR-50-1360, LCA-2TR-50-1510, LCA-2TR-50-1660, LCA-2TR-50-1810

Item specifics

Series:
LCA 2 Series
Resolution:
50 mm
Scanning range:
12 m
Protective field height:
160 mm - 1810 mm
2 Safety outputs (OSSD):
2 PNP
Response time:
3.5 ms - 13 ms
Connection type:
M12
Security level:
PLe2

Review

Description

For Euchner LCA 2 Series Safety Light Curtain Replacement Parameter
Brand
From network
DADISICK
Models
LCA-2TR-50-160
LCA-2TR-50-310
LCA-2TR-50-460
LCA-2TR-50-610
LCA-2TR-50-760
LCA-2TR-50-910
LCA-2TR-50-1060
LCA-2TR-50-1210
LCA-2TR-50-1360
LCA-2TR-50-1510
LCA-2TR-50-1660
LCA-2TR-50-1810
Beam spacing
50 mm
40 mm
Protected altitude
160 mm, 310 mm, 460 mm, 610 mm, 
760 mm, 910 mm, 1060 mm, 1210 mm, 
1360 mm, 1510 mm, 1660 mm,1810 mm
120 mm, 280 mm, 440 mm, 600 mm, 
760 mm, 920 mm, 1080 mm,1160 mm, 
1320 mm,1480 mm,1640 mm, 1800 mm
Scanning range
12 m
0.3 m - 15 m
Response time
3.5 ms - 13 ms
≤15 ms
Output method
2 PNP
2 PNP
Reliability and durability
IP65 / IP67
IP65
Connector
M12
M16
Housing cross-section
28 mm × 30 mm
35 mm × 51 mm
Safety Certificate
TÜV, UL
TÜV, UL, CE, RoHS, GB
We are able to reproduce the specific connection configuration of each brand with high level of accuracy.
Product model display instructions
The brands and specifications shown on this page are for product selection only. Our safety light curtain is a safety part made by DADISICK, not official brand Euchner's products. DAIDSICK offer replacement for official brand products. We are not the owner of the brands. If you need to buy official brand products, please contact the brand official representative.
Product recommendations
DADISICK Safety Light Curtains
Model:
QT04-40-120-2BD, QT08-40-280-2BD, QT12-40-440-2BD, QT16-40-600-2BD, QT20-40-760-2BD, QT24-40-920-2BD, QT28-40-1080-2BD, QT30-40-1160-2BD, QT34-40-1320-2BD, QT38-40-1480-2BD, QT42-40-1640-2BD, QT46-40-1800-2BD

FAQ
How do safety light curtains prevent guard gaps?
Safety light curtains prevent guard gaps in several ways:

1.Continuous Detection Zone: Safety light curtains create a continuous detection zone using multiple infrared beams. This zone is adjustable in height and width to cover the entire area that needs to be guarded.
2.No Dead Zones: Unlike other guarding devices, safety light curtains do not have dead zones where objects can pass undetected. The multiple beams ensure that any object, regardless of its size, shape, or orientation, will be detected if it passes through the light curtain.
3.Adjustable Resolution: The resolution of the safety light curtain, which determines the spacing between individual beams, can be adjusted. By reducing the beam spacing, a finer detection zone can be created, effectively eliminating small gaps that could allow objects to pass undetected.
4.Rapid Response Time: Safety light curtains have a very fast response time, typically in milliseconds. This means that as soon as an object interrupts one or more beams, the safety light curtain will immediately send a signal to stop the hazardous machine movement.
5.Redundancy: Many safety light curtain systems feature redundancy, meaning they have multiple layers of detection. If one beam is interrupted, the system will not necessarily stop the machine, but if multiple beams are interrupted, indicating a larger object, the system will trigger an emergency stop.
6.Monitoring and Diagnostics: Modern safety light curtain systems often include monitoring and diagnostic features that can detect when a beam is malfunctioning or if there is a gap in the detection zone. This allows for prompt maintenance and repair, ensuring the system's continued effectiveness.

By creating a continuous and adjustable detection zone with no dead zones, safety light curtains effectively prevent guard gaps, making them an effective safety solution for many industrial applications.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.
Safety Light Curtain Wiring Diagrams/Dimensional Drawings
safety light curtain Cable description
DADISICK Safety Light Curtain Cable Description
signal output selection (actual output of transistor working normally)
DADISICK Light Curtain Signal Output Selection
NPN output wiring diagram
DADISICK Light Curtain NPN Output Wiring Diagram
PNP output wiring diagram
DADISICK Light Curtain PNP Output Wiring Diagram
safety light curtain Dimension
DADISICK Safety Light Curtain Dimension
Safety-light-curtain QT Series Data Sheet
Safety-light-curtain QT Series User Manual

recommend